30 Installation and operating instructions
10.
Initial operation
10.6
Advanced functions
Caution!
Important factory default settings can be changed using the extended functions.
All the parameters must be set correctly to avoid damage to persons or property.
Intermediate position
Advice:
After changing the intermediate position,
a learning run must be carried out again.
The learning run is described in section 10.7.
1.
Operation mode/
Door CLOSED
2.
P
1x >10s
Start advanced
programming/
Programme remote
control intermediate
position
3.
3x <1s
Select Level 4
4.
P
1x <1s
In Level 4 / change to
Menu 1
5.
1x <1s
In Level 4 / change to
Menu 2
6.
P
1x <1s
Change to
programming mode
7.
Activate hand-held
transmitter
8.
Release hand-held
transmitter
9.
P
1x <1s
Save remote
control intermediate
position
10.
P
1x >5s
End programming
Remote control intermediate position
1.
Operating mode/
Door CLOSED
2.
P
1x >10s
Start advanced
programming/
Programme
intermediate position
3.
P
1x <1s
In Level 1/ Change to
Menu 3
4.
P
1x <1s
Change to
programming mode
5.
Set the
intermediate position
with (+) and (-)
6.
P
1x <1s
Save intermediate
position
7.
P
1x >5s
End programming
8.
Drive the door to
the CLOSED position
www.thegaragedoorcentre.co.uk