GL7p - Battery-powered, door-mounted electronic locker lock GL7p
Operation
60
HB_GL7p--EN_12
www.gantner.com
► Press the locker door shut.
► Press the button of the GL7p in using the DELETE MASTER data carrier for approximately 1 second.
o
The information on the data carrier is read and the LED flashes red until the DELETE MASTER data
carrier is removed.
► Remove the DELETE MASTER data carrier from the button.
o
All MASTER data carriers are now deleted from the lock. Next, the LED flashes green and red
alternately and the new MASTER data carriers can be programmed.
► Within 5 seconds, press the button of the GL7p in using the first MASTER data carrier for approximately 1
second.
o
When the data carrier is read correctly, the LED flashes green for 2 seconds.
► Remove the MASTER data carrier from the button.
o
The LED flashes green and red alternately. The second MASTER data carrier can now be
programmed.
► Repeat the process until all MASTER data carriers are programmed.
► If no action occurs after 5 seconds during programming of the MASTER data carriers, the GL7p automatically
returns to the normal operating mode and the new MASTER data carriers are saved in the lock.
6.5.2
OPEN MASTER Data Carrier (Optional Accessory)
The OPEN MASTER data carriers can unlock any GL7p
in a system. If a user’s data carrier is lost, an emergency
opening of the corresponding locker can be carried out using an OPEN MASTER data carrier. Compared to the
MASTER data carrier, the OPEN MASTER data carrier cannot lock the locker after it has been opened.
The OPEN MASTER data carrier is not included in the Basic Set and must be ordered separately as required. This
data carrier is only valid for the respective system.
NOTE!
The system operator must ensure that the OPEN MASTER
data carriers are stored in a safe location that is
secured against unauthorized access.
An OPEN MASTER data carrier can be used instead of an original MASTER data carrier. To program the OPEN
MASTER data carrier into a lock, read the data carrier at the lock. If already the max. amount of MASTER data carriers
(10) are programmed into the lock, the MASTER data carriers must first be deleted and the OPEN MASTER data
carrier must be programmed together with the required MASTER data carriers (max. total amount of 10).
6.5.3
DELETE MASTER Data Carrier
The DELETE MASTER data carrier is used to delete all the MASTER data carriers stored in the GL7p. See section
“6.5.1. MASTER Data Carrier”.
6.5.4
PROGRAM Data Carrier
For locks operating in personal locker mode, the PROGRAM data carrier is used to authorize data carriers so that
they can be used with the locker. The PROGRAM data carrier is also used to delete the existing authorizations of
personal lockers. See section
“6.3.4 Personal Locker Programming Card Mode”.