GL7p - Battery-powered, door-mounted electronic locker lock GL7p
Configuration
44
HB_GL7p--EN_12
www.gantner.com
5.4 Configuration Settings of the GL7p
The important configuration settings of the GL7p that can be adjusted in GAT Config Manager are explained in this
section. A list and brief explanation of every configuration setting available for the GL7p is provided in section
“5.4.10 Configuration Settings Table”.
5.4.1
Operating Mode
The GL7p can operate in one of five different operating modes. See
“6.3 Operating Modes" for a detailed
description of each mode. The operating mode setting is found here:
Configuration > Operating mode > General > Operating mode
► In the “Operating mode” menu, select either:
-
“FreeLocker”
-
“FreeLockerUniversal”
-
“FreeLockerUniqueNumber”
-
“PersonalLocker_ProgrammingCard”, or
-
“PersonalLocker_ExpiryDate”
5.4.2
Locker Number
The number of the locker where the GL7p is installed can be defined. The locker number setting is found here:
Configuration > Operating mode > General > LockerNumber
► Enter the locker number for the GL7p into the “Locker number” field.
5.4.3
Auto-Unlock
The auto-unlock function automatically unlocks the GL7p at a defined point in time or after a specific time has
elapsed after locking.
NOTE!
When this function is activated, the lock will always unlock at the defined point of time regardless of the
operating mode (see
The automatic unlocking function at a certain time after midnight is set via the following menu path:
Configuration > Operating mode > General > AutoUnlock [min]
► Enter a value representing the number of minutes into the field. The countdown time for unlocking begins at
00:00 (2
4 h). For example, a value of “300” means that the lock will unlock at 05:00 am. A value of “0” means
that the function is inactive.
To use the automatic unlocking function after a certain time has elapsed after locking, first enable the option in the
following configuration path: