GAT Access 6100 Terminal Series
Commissioning & Configuration
54
HB_GAT-ACCESS6100--EN_14
www.gantner.com
5.4.3
List of Configuration Settings
The following table lists all the configuration settings available for the GAT Access 6100 in GAT Config Manager. A
brief description and the format (where applicable) for each setting are shown in the table. Make sure to enter data in
the indicated format for settings such as time definitions, etc.
Options
Description
Format
Example(s)
Communication
Ethernet
Port number
Port used for communication with the device
Integer
8000
MAC address
The MAC address of the device (cannot be changed)
Hex
0123456789AB
DHCP enabled
If enabled, will use the IP settings from a DCHP server
Boolean
true
Static IP address
IP address of the device if DHCP is disabled
IPv4
Static subnet mask
Subnet mask of the device (if DHCP is disabled)
IPv4
Static primary DNS
Primary DNS address of the device (if DHCP disabled)
IPv4
Static secondary DNS
Secondary DNS address of the device (if DHCP disabled)
IPv4
Static default gateway
Default gateway of the device (if DHCP is disabled)
IPv4
NetBIOS name
NetBIOS name of the GAT Access 6100
Text
GA7764871234
5678
Dynamic IP address
IP address got from the DHCP Server
IPv4
Dynamic subnet mask
Subnet mask got from the DHCP Server
IPv4
Dynamic default gateway
Default gateway got from the DHCP Server
IPv4
100 MBit Ethernet enabled
Enable 100 MBit Ethernet link, 10 MBit if disabled
Boolean
true
Protocol
Terminal address
Address of the device
Integer
255
Type
Protocol type
Text
Leisure
Communication mode
Operation mode of the device
Text
Online
Leisure Omron mode active
Indicate if OMRON mode for online communication is
enabled (MIFARE and ISO 15693 data will be sent as
the old LEGIC
format).
Boolean
false
Button event enabled
Enable the button event command
Verify before CardIdent
Set if a verification with fingerprint is required before
CardIdent command is sent.
Boolean
false
Send Button Number
If this flag is enabled, the number of the pressed button
is transmitted in the "Button_Event" command.
Boolean
false
Enable Opto CardIdent
This option defines the behavior of the GAT Access
6100 in case an event at the optocoupler input “external
input” occurs:
Checked: A CardIdent with UID 0 is sent
Unchecked: An access without notification to the host is
triggered
Boolean
true
Enable second CardIdent
In case second identification is sent to the terminal and
a data carrier is read at the terminal, a second CardIdent
command is sent to the management software
Boolean
false
Hardware
Relay 1
Output for activation/unlocking of a turnstile or door
Default state
Inactive state of the Relay:
NO - Normally Open
NC - Normally Closed
Selection
NO / NC
Pulse time
Duration (ms) for how long the relay is active
Integer
300
Содержание GAT Access 6100 Series
Страница 10: ...GAT Access 6100 Terminal Series Table of Contents 10 HB_GAT ACCESS6100 EN_14 www gantner com...
Страница 18: ...GAT Access 6100 Terminal Series General Information 18 HB_GAT ACCESS6100 EN_14 www gantner com...
Страница 34: ...GAT Access 6100 Terminal Series Installation 34 HB_GAT ACCESS6100 EN_14 www gantner com...
Страница 42: ...GAT Access 6100 Terminal Series Electrical Connections 42 HB_GAT ACCESS6100 EN_14 www gantner com...
Страница 80: ...GAT Access 6100 Terminal Series Operation 80 HB_GAT ACCESS6100 EN_14 www gantner com...
Страница 84: ...GAT Access 6100 Terminal Series Updating the GAT Access 6100 84 HB_GAT ACCESS6100 EN_14 www gantner com...
Страница 92: ...GAT Access 6100 Terminal Series Troubleshooting FAQ 92 HB_GAT ACCESS6100 EN_14 www gantner com...