background image

Configuration

G&D VisionXS-IP-C-DP-UHR · 

30

English

Closing the web application

Use the 

Close

 button to end the active session of the web application.

How to close the web application:

1. Click on the 

user icon

 at the top right.

2. Click on 

Logout

 to exit the active session.

IMPORTANT: 

To protect the web application against unauthorised access, always 

use the 

Logout

 function after finishing your work with the web application.

Содержание VisionXS-IP-C-DP-UHR

Страница 1: ...Guntermann Drunck GmbH www gdsys de G D VisionXS IP C DP UHR A9100386 1 00 Installation und Bedienung DE EN Installation and Operation...

Страница 2: ...chluss G D bernimmt keine Gew hrleistung f r Ger te die nicht bestimmungsgem eingesetzt wurden nicht autorisiert repariert oder modifiziert wurden schwere u ere Besch digungen aufweisen welche nicht b...

Страница 3: ...utzt Hochfrequenzenergie und kann diese ausstrahlen Wenn es nicht gem der Anleitung installiert wird kann es Funkst rungen ver ursachen Es wird jedoch keinerlei Garantie daf r bernommen dass die St ru...

Страница 4: ...7 Konfiguration der globalen Netzwerkeinstellungen 17 Konfiguration der KVM over IP Verbindung 18 KVM over IP Verbindung des Arbeitsplatzmoduls konfigurieren 19 Konfiguration der Netzwerkschnittstelle...

Страница 5: ...out f r Eingaben innerhalb des OSDs ausw hlen 47 Wiederherstellung der Standardeinstellungen 48 Reset der Netzfilterregeln 49 Farbe der Informationseinblendung ndern 50 Anzeige der Informationseinblen...

Страница 6: ...uellen getrennt ist Ziehen Sie alle Netzstecker und alle Spannungsversorgungen am Ger t ab Disconnect all power sources Before installation ensure that the device has been disconnected from all power...

Страница 7: ...nden der elektrischen Sicherheit ist bei Ger ten mit L ftungs ffnungen nur eine aufrechte horizontale Einbauweise zul ssig Stolperfallen vermeiden Vermeiden Sie bei der Verlegung der Kabel Stolperfal...

Страница 8: ...rauchte Batterien d rfen nicht in den Hausm ll geworfen werden Beachten Sie die g ltigen Vorschriften zur Entsorgung elektronischer Produkte CAUTION Risk of explosion if the battery is replaced by an...

Страница 9: ...er Matrixswitch Module Sie k nnen die Module wahlweise als Extender oder Matrixswitch Module ver wenden Extender Module Konfigurieren Sie eine KVM over IP Verbindung zwischen dem Rechner und dem Arbei...

Страница 10: ...n auf Seite 22 Bei Beachtung der max L nge von Teilstrecken zwischen zwei aktiven Netzwerk komponenten jeweils bis zu 100 Meter ist die gesamte bertragungsl nge unbe schr nkt Lieferumfang Standardlief...

Страница 11: ...twahl der Ger te sicher dass die zul ssige Umgebungstemperatur siehe Technische Daten auf Seite 59 in der unmittelbaren N he eingehalten und nicht durch andere Ger te beeinflusst wird WICHTIG Bei Ger...

Страница 12: ...es Rechners mit dieser Schnittstelle Ver wenden Sie hierzu das Kabel DP Cable M M 2 HINWEIS Alle Ger tevarianten der VisionXS IP Serie k nnen mit einer externen Spannungsversorgung an der Power Schnit...

Страница 13: ...abels ist mit dem Gigabit Ethernet zu verbinden HINWEIS Die Audio Daten werden in der Standardeinstellung des KVM Exten ders zwischen den Switches bertragen Zus tzlich k nnen Sie im OSD die bertragung...

Страница 14: ...erreicht HINWEIS Alle Ger tevarianten der VisionXS IP Serie k nnen mit einer externen Spannungsversorgung an der Power Schnittstelle bei Desktop Geh usen Main Power betrieben werden Die Abbildungen in...

Страница 15: ...Massenspeicherger te und oder ein unterst tztes Display bzw Tablet anschlie en Aktivieren Sie den Generic USB Modus siehe USB Tastaturmodus oder Generic USB de aktivieren auf Seite 41 wenn Sie ein an...

Страница 16: ...hes Twisted Pair Kabel der Kategorie 6 oder h her ein Das andere Ende des Kabels ist mit dem Gigabit Ethernet zu verbinden HINWEIS Die Freischaltung des kostenpflichtig erh ltlichen Transm Redundancy...

Страница 17: ...tes erreicht HINWEIS Alle Ger tevarianten der VisionXS IP Serie k nnen mit einer externen Spannungsversorgung an der Power Schnittstelle bei Desktop Geh usen Main Power betrieben werden Die Abbildung...

Страница 18: ...zustand des Moduls Weitere Hinweise hierzu erhalten Sie im Kapitel Statusanzeigen ab Seite 58 On Screen Display des Arbeitsplatzmoduls Beim Start des Arbeitsplatzmoduls werden Informationen ber den St...

Страница 19: ...rbeitsplatzmoduls aufgeschaltet werden So schalten Sie ein bestimmtes Remote Target auf 1 Starten Sie das lokale On Screen Display mit dem Hotkey Alt Num Standard 2 W hlen Sie im Auswahl Men das aufzu...

Страница 20: ...ach der Inbetriebnahme anpassen Die IP Adressen und die KVM over IP Einstellungen sind wie folgt vorkonfiguriert WICHTIG Wenn Sie den KVM Extender als Matrixswitch Endger t mit dem IP Matrixswitch Con...

Страница 21: ...dresse des Rechnermoduls Host sowie die Angabe des Control Ports des Rechnermoduls erforderlich Die Konfiguration der Communication Ports und Data Ports werden automatisch zwi schen beiden Modulen aus...

Страница 22: ...ellungen stellen auch in komplexen Netzwerken sicher dass der KVM Extender aus allen Teilnetzwerken erreichbar ist So konfigurieren Sie die globalen Netzwerkeinstellungen 1 Verwenden Sie den Remote Ho...

Страница 23: ...stellungen folgende Daten 4 Bet tigen Sie die F2 Taste zur Speicherung der durchgef hrten nderungen Globale Einstellungen Bet tigen Sie die F8 Taste zur Auswahl des Betriebsmodus Static Verwendung von...

Страница 24: ...M Extender aus allen Teilnetzwerken erreichbar ist So konfigurieren Sie die globalen Netzwerkeinstellungen 1 Verwenden Sie den lokalen Hotkey Alt Num zum Aufruf des Arbeitsplatzmodul OSD 2 Bet tigen S...

Страница 25: ...ng und bet tigen Sie die Eingabetaste 4 Erfassen Sie im Abschnitt Lokal folgende Daten 5 Bet tigen Sie die F2 Taste zur Speicherung der durchgef hrten nderungen Globale Einstellungen Bet tigen Sie die...

Страница 26: ...alen Hotkey Alt Num zum Aufruf des Arbeitsplatzmodul OSD 2 Bet tigen Sie F11 zum Aufruf des Konfiguration Men s 3 W hlen Sie die Zeile KVM Verbindung und bet tigen Sie die Eingabetaste 4 W hlen Sie di...

Страница 27: ...rbindung Bandbreite limitieren In der Standardeinstellung verwendet der KVM Extender die maximal zur Verf gung stehende Bandbreite des Gigabit Ethernets Mittels manuellem Bandbreiten Management k nnen...

Страница 28: ...rdaten Communication Datenpa kete sowie die IP Pakete der Video Audio und RS232 Daten Data Datenpakete k nnen Sie je einen DSCP festlegen So konfigurieren Sie die DSCPs der IP Datenpakete 1 Verwenden...

Страница 29: ...en und alternativ die bertragung der Audio Daten deaktivieren So de aktivieren Sie die bertragung des Audio bzw RS232 Signals 1 Verwenden Sie den Remote Hotkey Strg Num zum Aufruf des Rechnermodul OSD...

Страница 30: ...tellungen und Verweise auf die ausf hrlichen Erl uterungen der Funktionen aufgef hrt Funktion Standardeinstellung Seite nderung des Hotkeys Strg 31 nderung der OSD Taste Num 32 On Screen Display mit d...

Страница 31: ...n Displays am Arbeitsplatz So starten Sie das On Screen Display 1 Starten Sie das On Screen Display mit dem Hotkey Strg Num Standard Funktion Standardeinstellung Seite Farbe der Informationseinblendun...

Страница 32: ...ezeigt Listenfeld Im Listenfeld werden die Men eintr ge des ausgew hlten Men s aufgef hrt Zu unterscheiden sind zwei Arten von Men eintr gen Men punkte mit Untermen Diese Eintr ge werden mit drei Punk...

Страница 33: ...Men ansicht und zeigt das bergeordnete Men an Falls Eingaben ge ndert aber nicht gespeichert wurden erhal ten Sie diesbez glich eine Meldung Tabulatortaste Verwenden Sie diese Taste um die Positionsma...

Страница 34: ...auf das Sprachk rzel der aktuellen Sprache rechts oben 2 Schalten Sie die zu verwendende Sprache mit einem Klick auf die gew nschte Sprache um HINWEIS Grundlegende Informationen zu den Systemvorausset...

Страница 35: ...der Webapplikation So beenden Sie die Webapplikation 1 Klicken Sie auf das Benutzersymbol rechts oben 2 Klicken Sie auf Abmelden um die aktive Sitzung zu beenden WICHTIG Verwenden Sie immer die Abmeld...

Страница 36: ...Eingabetaste 3 W hlen Sie die Zeile Hotkeys und bet tigen Sie die Eingabetaste 4 W hlen Sie im Abschnitt Modifizierer mindestens eine der aufgef hrten Hot key Modifizierertasten durch Markierung des...

Страница 37: ...onstaste durch Bet tigung der F8 Taste eine OSD Taste aus welche gemeinsam mit der bzw den Hotkey Modifizierer taste n den Aufruf des On Screen Displays bewirkt Num Num Taste Standard Pause Pause Tast...

Страница 38: ...Alt Taste Alt Gr OSD Aufruf mit doppeltem Druck auf die Alt Gr Taste Win OSD Aufruf mit doppeltem Druck auf die Windows Taste Shift OSD Aufruf mit doppeltem Druck auf die Umschalt Taste Drucken OSD A...

Страница 39: ...hnittstellen des Arbeits platz und des Rechnermoduls erforderlich OSD 1 Starten Sie das On Screen Display mit dem Hotkey Strg Num Standard 2 W hlen Sie die Zeile Arbeitsplatzeinrichtung und bet tigen...

Страница 40: ...32 Schnittstelle des Rechnermoduls einstellen m chten Klicken Sie auf den Reiter CON falls Sie den Betriebsmodus der RS232 Schnittstelle des Arbeitsplatzmoduls einstellen m chten 5 W hlen Sie im Feld...

Страница 41: ...f hrliche Informationen hierzu finden Sie im separaten Handbuch zur Webapplikation Config Panel So w hlen Sie den EDID Modus des KVM Extenders HINWEIS Beachten Sie bei der Erstinbetriebnahme sowie bei...

Страница 42: ...n Reiter Videokan le 4 Klicken Sie bei Einsatz eines Multichannel Ger tes auf den gew nschten Videokanal und anschlie end auf Konfiguration 5 W hlen Sie im Feld EDID Profil des Abschnitts Videokanal z...

Страница 43: ...ich zu signalisieren wird das zuletzt empfan gene Bild wahlweise mit einem farbigen Rahmen und oder der Einblendung Frozen und der vergangenen Zeit seit dem Verbindungsabbruch dargestellt Config Panel...

Страница 44: ...ungsabbruch Rahmen OSD Anzeige des farbigen Rahmens frame und Einblendung des Hinweises Eingefroren OSD 5 Bet tigen Sie die F2 Taste zur Speicherung der durchgef hrten nderungen Config Panel 1 Klicken...

Страница 45: ...eingestellen 3 W hlen Sie in der Zeile DDC CI Unterst tzung durch Bet tigung der F8 Taste zwischen folgenden Optionen aus Die bertragung von DDC CI Signalen ist deaktiviert Standard CPU Monitor Die b...

Страница 46: ...en Die folgende Tabelle listet die unterst tzten USB Tastaturen auf Displays und Tablets Sie k nnen den am KVM Extender angeschlossenen Rechner mit einem der unterst tzten Displays oder Tablets bedien...

Страница 47: ...r Generic USB Modus unterst tzt viele der am Markt erh ltlichen USB Massenspeicherger te und Eingabeger te Der Betrieb eines bestimmten Ger tes im Generic USB Modus kann nicht gew hrleistet werden EIN...

Страница 48: ...des Scancode Sets OSD 1 Starten Sie das On Screen Display mit dem Hotkey Strg Num Standard 2 W hlen Sie die Zeile Arbeitsplatzeinrichtung und bet tigen Sie die Eingabetaste falls Sie das Scancode Set...

Страница 49: ...ellen m chten Klicken Sie auf den Reiter CON falls Sie die Einstellung des entfernten Arbeitsplatzes am CON Modul einstellen m chten 5 W hlen Sie im Feld Scancode Set des Abschnitts Konfiguration zwis...

Страница 50: ...agiert So de aktivieren Sie die Reinitialisierung der USB Eingabeger te OSD 1 Starten Sie das On Screen Display mit dem Hotkey Strg Num Standard 2 W hlen Sie die Zeile Arbeitsplatzeinrichtung und bet...

Страница 51: ...im Feld USB Auto Refresh des Abschnitts Konfiguration eine der fol genden Optionen Nur fehlerhafte Ger te Der Status der USB Ger te wird berwacht Falls die Kommunikation zu einem USB Ger t gest rt ist...

Страница 52: ...en Sie auf den Reiter Allgemein 4 Klicken Sie auf den Reiter CPU falls Sie den Bildschirmschoner des lokalen Arbeitsplatzes am CPU Modul einstellen m chten Klicken Sie auf den Reiter CON falls Sie den...

Страница 53: ...ie auf Speichern HINWEIS Diese Funktion kann ausschlie lich ber die Webapplikation ausge f hrt werden HINWEIS ffnen Sie das lokale OSD des Arbeitsplatzmoduls mit dem local hotkey Standard Alt Num fall...

Страница 54: ...s Alle Einstellungen zur cksetzen Alle Einstellungen des Ger tes zur cksetzen Nur Einstellungen f r lokales Netzwerk zur cksetzen Ausschlie lich die lokalen Netzwerkeinstellungen zur cksetzen Nur Eins...

Страница 55: ...Sie das On Screen Display mit dem Hotkey Strg Num Standard 2 W hlen Sie die Zeile Arbeitsplatzeinrichtung und bet tigen Sie die Eingabetaste 3 W hlen Sie die Zeile Pers nliches Profil und bet tigen S...

Страница 56: ...Eingabetaste 3 W hlen Sie die Zeile Pers nliches Profil und bet tigen Sie die Eingabetaste 4 W hlen Sie in der Zeile Einblendung durch Bet tigung der F8 Taste zwischen folgenden Optionen aus Informat...

Страница 57: ...en Sie in der Zeile OSD Transparenz durch Bet tigung der F8 Taste zwi schen folgenden Optionen hoch hohes Durchscheinen des Bildschirminhalts mittel mittleres Durchscheinen des Bildschirminhalts Stand...

Страница 58: ...e die Zeile Arbeitsplatzeinrichtung und bet tigen Sie die Eingabetaste 3 W hlen Sie die Zeile Pers nliches Profil und bet tigen Sie die Eingabetaste 4 W hlen Sie die Zeile Timeout der OSD Sitzung s un...

Страница 59: ...n Sie die Eingabetaste An der aktuellen Position der Informationsein blendung erscheint das rechts abgebildete Men 5 Verwenden Sie die Pfeiltasten oder die Maus um das Men an die gew nschte Position z...

Страница 60: ...auslesen lassen oder diese unzul ssige Eintr ge enthalten werden die Informationen wenn m glich vervollst ndigt oder korrigiert Ermittlung der Netzwerkeinstellungen ber den Service Port Falls Ihnen di...

Страница 61: ...en Bits pro Sekunde 115 200 Datenbits 8 Parit t Keine Stoppbits 1 Flusssteuerung Keine 3 Verwenden Sie das mitgelieferte USB Servicekabel um den Rechner mit der Ser vice Buchse an der Frontseite des A...

Страница 62: ...tsprechenden Pins auf Arbeitsplatzmodul Rechnermodul RS232 Stecker RS232 Buchse Pin Nr Leitung Arbeitsplatz modul Rechner modul 1 DCD Data Carrier Detect Eingang Ausgang 2 RxD Receive Data Eingang Aus...

Страница 63: ...alten Sie den Port mit einem Feature Key frei aus Keine Verbindung zu einer Gegenstelle hergestellt Network gr n an Die Verbindung mit dem Netzwerk wurde erfolgreich aufgebaut gelb an Es konnte keine...

Страница 64: ...erial bertragung zur G D Gegenstelle bertragungsart KVM over IP Kanalanzahl 1 1 optional Der zweite bertragungskanal kann mit einem optional k uflichen Feature Key freigeschaltet werden Reichweite max...

Страница 65: ...60Hz 2K 2K 2560 1600 60Hz 3840 2160 60Hz Ultra HD 60Hz 4096 2160 60Hz 4Kp60Hz Weitere nach VESA und CEA standardi sierte Aufl sungen sind im Rahmen der unterst tzten Videobandbreite Pixelrate und Hor...

Страница 66: ...hmontage Luftfeuchte 20 bis 80 nicht kondensierend Lagerumgebung Temperatur 20 C bis 60 C Luftfeuchte 15 bis 85 nicht kondensierend VISIONXS IP CON C DP UHR Schnittstelle f r entfernten Arbeitsplatz M...

Страница 67: ...euchte 20 bis 80 nicht kondensierend Lagerumgebung Temperatur 20 C bis 60 C Luftfeuchte 15 bis 85 nicht kondensierend VISIONXS IP CON C DP UHR DT Schnittstelle f r entfernten Arbeitsplatz Monitor 1 Di...

Страница 68: ...te 20 bis 80 nicht kondensierend Lagerumgebung Temperatur 20 C bis 60 C Luftfeuchte 15 bis 85 nicht kondensierend VISIONXS IP CON C DP UHR AR DT Schnittstelle f r entfernten Arbeitsplatz Monitor 1 Dis...

Страница 69: ...RS232 1 1 optional RJ45 Buchse 1 GBit s 10 GBit s Stromaufnahme Hauptstromversorgung 12 VDC 1 9 A Geh use Material Aluminium eloxiert Dimensionen B H T 109 39 8 184 mm Gewicht ca 1 0 kg Einsatzumgebu...

Страница 70: ......

Страница 71: ...Deutsch...

Страница 72: ...G D will not provide warranty for devices that Are not used as intended Are repaired or modified by unauthorized personnel Show severe external damages that was not reported on the receipt of goods Ha...

Страница 73: ...s equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However ther...

Страница 74: ...network interface 17 Configuring the global network settings 17 Configuring a KVM over IP connection 18 Configuring a KVM over IP connection of a user module 19 Configuring the network interface 19 Co...

Страница 75: ...aver 46 Selecting a keyboard layout for inputs via OSD 47 Resetting the default settings 48 Resetting the netfilter rules 49 Changing the colour of the information display 50 Information display 51 Ad...

Страница 76: ...onnect all power plugs and all power supplies of the device D branchez toutes les sources d alimentation Avant l installation assurez vous que l appareil a t d branch de toutes les sources d alimentat...

Страница 77: ...n position For reasons of electric safety the device has to be installed upright and horizontally Avoid tripping hazards Avoid tripping hazards while laying cables Only use a grounded voltage source O...

Страница 78: ...t dispose of batteries in municipal waste Check local regulations for the disposal of electronic products ATTENTION Il y a danger d explosion s il y a remplacement incorrect de la batterie Mettre au r...

Страница 79: ...odules You can use the modules as either extender or matrix switch modules Extender modules Configure a KVM over IP connection between the computer and the user module The configured connection betwee...

Страница 80: ...width on page 22 When observing the max length of sections between two active network components up to 100 meters each the entire transmission length is unrestricted Package contents Standard package...

Страница 81: ...vices please ensure to comply with the ambient temperature limit see Technical data on page 59 ff close to the device The ambient temperature limit must not be influenced by other devices IMPORTANT Do...

Страница 82: ...ble M M 2 cable to connect the computer s video output to this interface NOTE All device variants of the VisionXS IP series can be operated with an external power supply at the Power interface for des...

Страница 83: ...sory into this interface Connect the other end of the Gigabit Ethernet NOTE By default the KVM switch transfers audio data between switches In addition you can enable the transmission of RS232 data an...

Страница 84: ...ll device variants of the VisionXS IP series can be operated with an external power supply at the Power interface for desktop casings Main Power The illustrations in this chapter show the desktop vari...

Страница 85: ...e devices and or a supported display or tablet to this interface Activate the generic USB mode see De Activating an USB keyboard or the Generic USB mode on page 41 if you want to connect another USB i...

Страница 86: ...air cable which is available as accessory into this interface Connect the other end of the Gigabit Ethernet NOTE The activation of the Transm Redundancy feature activates the Transmission 2 interface...

Страница 87: ...TE All device variants of the VisionXS IP series can be operated with an external power supply at the Power interface for desktop casings Main Power The illustrations in this chapter show the desktop...

Страница 88: ...odule s operating status For further information about this topic also see the chapter Status LEDs on page 58 ff On screen display of the user module When starting the user module information about th...

Страница 89: ...rgets can be connected via the local OSD of the user module How to access a remote target via on screen display 1 Start the local on screen display with the Alt Num hotkey default 2 Use the arrow keys...

Страница 90: ...nfigura tion of both modules after their initial operation Both the IP addresses and the KVM over IP settings are preconfigured as follows IMPORTANT If you use the KVM extender as a matrix module with...

Страница 91: ...fied to establish a KVM over IP connection through the user module The configuration of both the communication ports and the data ports are automati cally exchanged between the two modules NOTE Use th...

Страница 92: ...ks global network settings ensure that the KVM extender is available from all partial networks How to configure global network settings 1 Use the remote hotkey Ctrl Num to open the OSD of computer mod...

Страница 93: ...ter module 2 Select the entry KVM connection and press Enter 3 Enter the following data under Network setting 4 Press F2 to save your settings Global preferences Press F8 to select the global preferen...

Страница 94: ...ks How to configure global network settings 1 Use the local hotkey Alt Num to open the OSD of the user module 2 Press F11 to open the Configuration menu 3 Select the entry Network setup and press Ente...

Страница 95: ...the user module 2 Press F11 to open the Configuration menu 3 Select the entry KVM Connection and press Enter 4 Enter the following data under Local 5 Press F2 to save your settings Global preferences...

Страница 96: ...to open the OSD of the user module 2 Press F11 to open the Configuration menu 3 Select the entry KVM Connection and press Enter 4 Select the entry Remote target and press Enter 5 Use the arrow keys to...

Страница 97: ...on Limiting the bandwidth By default the KVM extender uses the maximum available bandwidth of a Gigabit Ethernet By means of manual bandwidth management you can adapt the transmis sion to different ba...

Страница 98: ...control data Communication data packets as well as the IP packets of the video audio and RS232 data Data data packets How to configure the DSCPs of the IP data packets 1 Use the remote hotkey Ctrl Nu...

Страница 99: ...ion you can enable the transmission of RS232 data and alternatively disable the transmission of audio data How to de activate the transmission of audio or RS232 signals 1 Use the remote hotkey Ctrl Nu...

Страница 100: ...rences to detailed descrip tions of the functions Function Default setting Page Changing hotkeys Ctrl 31 Changing the OSD key Num 32 Opening the on screen display via double keypress turned off 33 Adj...

Страница 101: ...at the console How to open the on screen display 1 Press Ctrl Num standard to open the on screen display Function Default setting Page Changing the colour of the information display light green 50 Inf...

Страница 102: ...tle of the current menu List field The list field shows the menu items of the selected menu there are two types of menu items Menu items with submenus These items are displayed with three dots in the...

Страница 103: ...en a submenu Esc This key closes the displayed menu and shows the superior menu A message is shown if entries are changed but not saved Tab key Use this key to move the cursor within the list field fr...

Страница 104: ...How to change the language of the web application 1 Click the language identifier of the current language in the upper right corner 2 Switch the language to be used by clicking on the desired language...

Страница 105: ...active session of the web application How to close the web application 1 Click on the user icon at the top right 2 Click on Logout to exit the active session IMPORTANT To protect the web application...

Страница 106: ...n display 2 Select the row System setup and press Enter 3 Select the row Hotkey and press Enter 4 Under Modifier select at least one of the listed hotkey modifiers by selecting the box with the arrow...

Страница 107: ...ctionkey press F8 to select an OSD key Now you can open the OSD when pressing the OSD key together with the hotkey modifier s Num Num key default Pause Pause key Insert Insert key Delete Delete key Ho...

Страница 108: ...ice Alt Gr OSD is opened by pressing the Alt Gr key twice Win OSD is opened by pressing the Windows key twice Shift OSD is opened by pressing the Shift key twice Print OSD is opened by pressing the Pr...

Страница 109: ...apters you also need to change the operating mode of the RS232 interfaces of both the console and the computer module OSD 1 Press Ctrl Num default to open the on screen display 2 Select the row Consol...

Страница 110: ...mputer module Click on the tab CON if you want to adjust the operating mode of the RS232 interface of the console module 5 Select one of the options of the Serial communication field under the para gr...

Страница 111: ...the EDID profile of a monitor The KVM extender then transmits it to the connected com puter Detailed information about this topic is given in the separate manual of the web application Config Panel H...

Страница 112: ...Configuration 3 Click on the tab Video channels 4 When using a multi channel device click on the desired video channel and then click on Configuration 5 In the EDID profile field of the Video channel...

Страница 113: ...t available image can be displayed with either a coloured frame and or a Frozen popup and the time passed since the connection has been interrupted Config Panel 1 In the menu click on KVM extender 2 C...

Страница 114: ...frame and Frozen OSD 5 Press F2 to save your settings Config Panel 1 In the menu click on KVM extender 2 Click on the computer module CPU you want to configure and then click on Configuration 3 Click...

Страница 115: ...he transmission of DDC CI signals is disabled default CPU monitor The transmission of DDC CI signals is carried out exclusively from the CPU to the monitor bidirectional The transmission of DDC CI sig...

Страница 116: ...keyboards The following table lists the supported USB keyboards Displays and Tablets You can operated the computer connected to the KVM extender via a supported display or tablet IMPORTANT The generi...

Страница 117: ...DEVICE SETTING any USB mass storage or USB HID device Generic USB IMPORTANT The generic USB mode supports many available USB mass storage devices and HID devices However being able to operate particul...

Страница 118: ...How to change the setting of the scancode set OSD 1 Press Ctrl Num default to open the on screen display 2 Select the row Console setup and press Enter if you want to adjust the scan code set of the r...

Страница 119: ...n on the CPU module Click on the tab CON if you want to configure the setting of the remote workstation on the CON module 5 In the Scancode set field of the Configuration section select one of the fol...

Страница 120: ...se no longer reacts to your inputs during operation How to enable disable reinitialisation of USB input devices OSD 1 Press Ctrl Num default to open the on screen display 2 Select the row Console setu...

Страница 121: ...workstation on the CON module 5 In the USB auto refresh field of the Configuration section select one of the fol lowing options Only faulty devices The status of the USB devices is monitored If commun...

Страница 122: ...hen click on Configuration 3 Click on the tab General 4 Click on the tab CPU if you want to configure the screensaver of the local workstation on the CPU module Click on the tab CON if you want to con...

Страница 123: ...ican Portuguese Swedish 5 Click on Save NOTE This function can be carried out only via web application NOTE Open the local OSD of the user module by pressing the local hotkey default Alt Num if you wa...

Страница 124: ...stem 2 Click on System defaults 3 Select the scope of the recovery Reset all settings Reset all settings of the device Reset only local network settings Reset only local network settings Reset only KV...

Страница 125: ...dark turquoise silver light green yellow blue fuchsia light turquoise white OSD 1 Press Ctrl Num default to open the on screen display 2 Select the row Console setup and press Enter 3 Select the row P...

Страница 126: ...er 3 Select the row Personal Profile and press Enter 4 Under Display press F8 to select between the following options Off information display is turned off Temporary information display is shown tempo...

Страница 127: ...Profile and press Enter 4 Under OSD transparency press F8 to select on of the following options high high transparency of the screen content average average transparency of the screen content default...

Страница 128: ...OSD 1 Press Ctrl Num default to open the on screen display 2 Select the row Console setup and press Enter 3 Select the row Personal Profile and press Enter 4 Select the row Close OSD when inactive for...

Страница 129: ...setup and press Enter 3 Select the row Personal Profile and press Enter 4 Select the row Set display position and press Enter The message on the right is shown at the current position of the informati...

Страница 130: ...that the display cannot be read without errors or that the entries are invalid the information is completed or corrected if possible Determining network settings via service port If you do not know th...

Страница 131: ...tings Bits per second 115 200 Data bits 8 Parity None Stop bits 1 Flow control None 3 Use the supplied USB service cable to connect the computer to the Service port on the front panel of the user or...

Страница 132: ...assigned to the according pins User module Computer module RS232 plug RS232 socket Pin no Line User module Computer module 1 DCD Data Carrier Detect Input Output 2 RxD Receive Data Input Output 3 TxD...

Страница 133: ...the port with a feature key off Connection to remote station has not been established Network green on The connection to the network has been successfully established yellow on A connection could not...

Страница 134: ...Transmission type KVM over IP Number of channels 1 1 optional The second transmission channel can be unlocked with an optionally purchasable feature key Range max 100 meters Other interfaces Network...

Страница 135: ...60Hz 2K 2K 2560 1600 60Hz 3840 2160 60Hz Ultra HD 60Hz 4096 2160 60Hz 4Kp60Hz 1920 1080i 60Hz 1440 576i 50Hz Further resolutions standardized accord ing to VESA and CEA are possible within the support...

Страница 136: ...ble mounting Air humidity 20 to 80 non condensing Storage environment Temperature 20 C to 60 C Air humidity 15 to 85 non condensing VISIONXS IP CON C DP UHR Interface for remote console Monitor 1 Disp...

Страница 137: ...ng Air humidity 20 to 80 non condensing Storage environment Temperature 20 C to 60 C Air humidity 15 to 85 non condensing VISIONXS IP CON C DP UHR DT Interface for remote console Monitor 1 DisplayPort...

Страница 138: ...ir humidity 20 to 80 non condensing Storage environment Temperature 20 C to 60 C Air humidity 15 to 85 non condensing VISIONXS IP CON C DP UHR AR DT Interface for remote console Monitor 1 DisplayPort...

Страница 139: ...2 1 1 optional RJ 45 socket 1 GBit s 10 GBit s Current consumption Main power supply 12 VDC 1 9 A Casing Material anodised aluminium Dimensions W H D 109 39 8 184 mm Weight approx 1 0 kg Operating env...

Страница 140: ......

Страница 141: ...English...

Страница 142: ......

Страница 143: ...English...

Страница 144: ...bere Leimbach 9 57074 Siegen Germany www gdsys de sales gdsys de Das Handbuch wird fortlaufend aktualisiert und im Internet ver ffentlicht The manual is constantly updated and available on our website...

Отзывы: