background image

ZNS Installation and Operation Manual

Issue 4 12/4/98

GENERAL INFORMATION

The Gamewell Company thanks you for choosing the ZNS Microprocessor based fire alarm control panel.
As with all our products we have taken great care to insure that we have provided a quality product.  To
receive maximum benefit and many years of reliable service we would like to make the following
recommendations:

1.

Read this manual carefully

 and in it's entirety before proceeding with the installation of the

ZNS panel.

2.

Never

 make any connections 

with the power connected.

3.

Gamewell spends many hours testing devices that are supplied by Gamewell to be used with
it's control panels to verify compatibility. 

To maximize system performance, and minimize

risk of damage to the equipment, we suggest using all Gamewell Components.

4.

There is no substitute for proper maintenance and testing 

of this or any life safety

product.  Gamewell recommends testing and maintenance of your ZNS in accordance with the
guidelines set forth by the National Fire Protection Association,  to be done on a regular basis,
as a minimum.

5.

This manual should be stored with the ZNS panel

 for future reference, and should not be

removed, providing reference to the operation and programming of the installed ZNS

Thank you again for choosing Gamewell.  If you have any comments regarding your ZNS panel or other
Gamewell products, please feel free to contact us at:

The Gamewell Company

Product Marketing Department

60 Pleasant Street

Ashland, MA 01721

Technical Manuals Online! - http://www.tech-man.com

firealarmresources.com

Содержание ZNS

Страница 1: ...AL FIRE ALARM CONTROL PANEL Installation Operation Manual The Gamewell Company 60 Pleasant Street Part No 71774 Ashland MA 01721 Issue 4 12 4 98 PROPRIETARY MATERIAL Technical Manuals Online http www...

Страница 2: ...The Gamewell Company Such information and technical drawings may not be copied or reproduced in any manner or disclosed to organizations that might be competitive to Gamewell without the express prio...

Страница 3: ...ity To maximize system performance and minimize risk of damage to the equipment we suggest using all Gamewell Components 4 There is no substitute for proper maintenance and testing of this or any life...

Страница 4: ...lt Operation 2 Auxiliary Power 2 Programming 2 Zone Card 2 Indicators 2 Alarm Disconnect 2 Low High Current Operation 2 Addressing 2 Zone Programming 2 Programming 3 Power Requirements 3 Appendix A 4...

Страница 5: ...one modules INSTALLATION AND WIRING Mechanical Two cabinet sizes are available for the ZNS the smaller is used to house a 2 to 16 zone system and the larger is used on 2 to 32 zone systems 21 W x 25 5...

Страница 6: ...e The standard zone module has a red and yellow the supervisory zone has two yellow LED s Alarm Disconnect Each zone of the 31016 2 zone card has a disconnect switch located next to the LEDs When this...

Страница 7: ...nstalled W2A Installed Class A W1A Removed W2A Removed Zone cards are shipped with all jumpers installed Class B Alarms Latched Power Requirements The ZNS common card draws 2 mA from the 24V supply an...

Страница 8: ...No Apollo Part No Qty Gamewell Model No Apollo Part No 71033 55000 350 71036 45681 200 71034 55000 250 71086 45681 220 71035 55000 150 20 71086 LOW 45681 232 71035 160 55000 151 71086 GREEN 45681 231...

Страница 9: ...FW 71741 ET90 2430C FW 71543 AS 2415 VFR 71685 NH 12 24 R 71742 ET90 2475C FW 71544 AS 241575 VFR 71686 NS 2415W FR 71743 ET90 24100C FW 71545 AS 2430 VFR 71687 NS 241575W FR 71744 E70 2415W FR 71546...

Страница 10: ...Drawings D M781 Ass y of ZNS 16 Zones D M780 Ass y of ZNS 32 Zones A M1104 Mounting Instruction Card Guide A M1105 Configuring of 2 Zone Card D W1171 Wiring ZNS System A W544 Wiring ZNS 2 Zone Card Te...

Отзывы: