2.
Heating Resistances
Each heater has four 1500 W elements connected in parallel, which give the system a total
power of 6000 W. If under normal conditions of ambient temperature, it is not possible to reach
the temperature required in two or three minutes, it is possible that one or several heating
elements are not working.
To check the state of the element, proceed as follows:
With the main switch off check with a tester that reading the total value of the heater resistance
is indicated in the table according to the power, voltage and number for each installed heater
elements, a higher value would indicate that one or more elements are faulty .
Disconnect them and check that the individual value of each element is as shown in the table
according to the installed power and voltage.
Table 1. Elements Values List
(W)
(V)
x1
(Ω)
x2
(Ω)
x4
(Ω)
x6
(Ω)
450
230
117±2
58±2
29±2
19±2
900
230
58±2
29±2
14±2
9±2
900
400
177±2
88±2
44±2
29±2
1250
230
42±2
21±2
10±2
7±2
1250
400
128±2
64±2
32±2
21±2
1250
440
154±2
77±2
38±2
25±2
1500
230
35±2
17±2
8±2
5±2
1500
400
106±2
53±2
26±2
17±2
1500
440
129±2
64±2
32±2
21±2
1800
230
29±2
14±2
7±2
4±2
1800
400
88±2
44±2
22±2
14±2
1800
440
107±2
53±2
26±2
17±2
2000
230
26±2
13±2
6±2
4±2
2000
400
80±2
40±2
20±2
13±2
2000
440
96±2
48±2
24±2
16±2
Under extreme environmental conditions, the heater might be affected and fail to reach the
required temperature. In this case, put the unit in a more favorable place, or use an auxiliary
heating system.
3.
Automatic Switch
This protects the elements against any possible change in voltage. With the general switch
turned off, open the control panel and make sure the switch is activated (see electrical
diagram), otherwise activate it.