Product Installation Guidelines 

Version 1, 14 September 2022, Page 

1

 of 

4

 

CliniMix

®

 BS Lead Safe Thermostatic Cartridge 

Assembly for CMV2 Low Flow 

 

PRODUCT CODES 

100.91.10.20 

 

SPECIFICATIONS

 

 

Designed to be used with CliniMix

®

 CMV2 only. 

 

Lead Safe

™ brass construction.* 

 

IMPORTANT:  All CliniMix

®

 spare parts are tested and leave our premises in good working order. 

 

*As ‘lead free’ is not currently defined by law in Australia and New Zealand, we have based our definition of Lead Safe™ on the requirements of s1417 of the USA’s Safe Drinking 
Water Act (SDWA

) and the relevant US standards NSF61 / NSF372. The SDWA defines ‘lead free’ as “not more than a weighted average of 0.25% lead when used with respect 

to the wetted surface of pipes, pipe fittings, plumbing fittings and fixtures”.

 

 

TECHNICAL DATA 

Inlet

 

N/A 

Outlet 

N/A 

Headwork 

N/A 

Working Pressure Range (kPa)  

Min 

20 

Max

 

500 

Working Temperature Range (°C) 

Min 

Max

 

85 

Nominal Flow Rate (LPM)  

N/A 

Construction 

Brass 

Finish 

Brass 

NOTE: Galvin Engineering continually strive to improve their products. Specifications may change without 
notice.  

 

 

 

DIMENSIONS

 

 

AS 4032.4 Lic. W  A21   

SA   lobal

Содержание CliniMix 100.91.10.20

Страница 1: ...based our definition of Lead Safe on the requirements of s1417 of the USA s Safe Drinking Water Act SDWA and the relevant US standards NSF61 NSF372 The SDWA defines lead free as not more than a weighted average of 0 25 lead when used with respect to the wetted surface of pipes pipe fittings plumbing fittings and fixtures TECHNICAL DATA Inlet N A Outlet N A Headwork N A Working Pressure Range kPa M...

Страница 2: ...mains and deinstall Spout Close off both hot and cold water mains or power main Ensure water is not flowing when hand waving in front of the sensor Loosen grab screw to unlock the spout Pull and gently remove the spout Removing the disinfection key cover plug might help with detaching the faceplate in next steps 2 Remove the faceplate Loosen the grub screw shown on above picture Unscrew the lockin...

Страница 3: ...r part of the spout if the main power remained on Remove the cartridge by hand 6 Assembly and testing New cartridge can now be re installed by screwing into the mixer body until it reaches a firm stop The cartridge should be tightened to a torque of 15Nm Re install or install new plastic lock supplied with the new cartridge When service is complete slowly turn the cold water isolation ball valve t...

Страница 4: ...nty are complied with The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty and Galvin Engineering Pty Ltd shall not be responsible for any incidental special or consequential damages including without limitation lost profits or the cost of repairing or replacing other property which is damaged if this product does not wo...

Отзывы: