Revision 1 

2021/10/01 

Important Safety Guidelines for Galvanic Applied Sciences Inc., 

ACCUCHROME Gas Chromatograph 

 

This equipment must be used as specified by the manufacturer or overall safety 

will be impaired.  

Access to this equipment should be limited to authorized, trained personnel ONLY. 

Due to the thermal mass of the hardware, cooling of the items takes substantial 

time. 

Observe all warning labels on the analyzer enclosures. 

The analog outputs and alarm relay contacts may be powered by a source separate from the  
one (s) used to power the analyzer system.  Disconnecting the AC Mains Source (s) may not 
remove power from the analog output signals or the alarm relay contacts. 

Any safety recommendations or comments contained herein are suggested guidelines only. 
Galvanic Applied Sciences Inc. bears no responsibility and assumes no liability for the use and/or 
implementation of these suggested procedures. 

This system, when operating in its normal mode, and/or when it is being serviced, maintained, 
installed and commissioned contains items which may be hazardous to humans if handled or 
operated incorrectly or negligently. These hazards include, but are not limited to: 

  High Voltage Electrical Energy 

  Toxic and Explosive Gases 

  High Temperature Surfaces 

 Access to this equipment should be limited to only to authorized, trained 

personnel.  

 

Содержание AccuChrome

Страница 1: ...ADDENDUM 1 NEMS C9 Module P N MA2963 A1 Revision 1 2021 October 1 Galvanic Applied Sciences Inc 7000 Fisher Road S E Calgary Alberta T2H OW3 Canada Phone 403 252 8470 Fax 403 255 6287 E mail info galv...

Страница 2: ...on in this manual is subject to change without notice and does not represent a commitment on the part of Galvanic Applied Sciences Inc No part of this manual may be reproduced or transmitted in any fo...

Страница 3: ...ARATION COLUMN 4 3 6 DETECTOR 4 SECTION 4 INSTALLATION 5 4 1 DIMENSIONS AND SPACE REQUIREMENTS 5 4 2 SAMPLING CONSIDERATIONS 7 4 1 ELECTRICAL REQUIREMENTS 7 4 2 INSTALLATION STEPS 8 SECTION 5 CONFIGUR...

Страница 4: ...y The Warning symbol indicates a hazardous situation that if not avoided could result in death or serious injury The Caution symbol with the safety alert symbol indicates a hazardous situation that if...

Страница 5: ...necting the AC Mains Source s may not remove power from the analog output signals or the alarm relay contacts Any safety recommendations or comments contained herein are suggested guidelines only Galv...

Страница 6: ...ity transportation charges prepaid or accept the return of the defective Product and refund the purchase price paid by Buyer for that Product If requested by Buyer Seller will use its best efforts to...

Страница 7: ...e processor or software or firmware will be uninterrupted or error free The warranty herein applies only to Products within the agreed country of original end destination Products transferred outside...

Страница 8: ...ds measurement to the hexane isomers heptane isomers octane isomers and nonane isomers in parallel The results of the two analyses are combined to arrive at a full C9 analysis of hydrocarbon gases If...

Страница 9: ...t package Figure A1 shows the APIX NEMS device Figure A1 The APIX Device 3 2 Mounting The APIX device is mounted inside an electrical enclosure for use in hazardous conditions The device plugs into an...

Страница 10: ...Revision 1 3 2021 10 01 Figure A2 APIX Device Mounting Figure A3 NEMS C9 Module assembly shown with explosionproof enclosure for Class I Div 2...

Страница 11: ...e Gas Requirements Gas Stream Min Max Pressure bar Design Pressure bar Min Max Flow Rate cm min Design Flow Rate cm min Carrier Input 1 0 2 0 1 0 10 20 10 Sample Input 0 3 1 5 1 0 50 100 50 Sample Ven...

Страница 12: ...e room for opening the cabinet doors for maintenance and repair procedures Complete dimensional information is provided in Figure A4 When the system is installed leave 6 between the unit and other dev...

Страница 13: ...Revision 1 6 2021 10 01 Figure A4 Physical Dimensions Class I Div 1 ACCUCHROME Chromatograph...

Страница 14: ...e divides a singular sample gas stream between the GC and NEMS module sections of the unit Refer to Section 3 3 of the AccuChrome manual for more information 4 1 Electrical Requirements The AccuChrome...

Страница 15: ...C tab in the righthand side navigation menu NEMS Setup and NEMS Status Modifying the component table NEMS parameters and viewing the NEMS status requires an administrator login Refer to Section 5 of...

Страница 16: ...dditional pressure is relieved through the Sample gas vent Run Time The duration in seconds permitted for analysis of the Sample Gas by the NEMS device Injector Thermal Zone Active This checkbox indic...

Страница 17: ...mation about the NEMS State current NEMS Run Time in seconds and the Cabinet Temperature You can also view information about the injector temperature and column temperature Set points may be entered f...

Страница 18: ...hromatogram There are two separate chromatograms one shows the chromatogram generated by the TCD while the other shows the chromatogram generated by the NEMS module To view the signal from the NEMS mo...

Страница 19: ...ing Trace Selection to Modify Viewing Properties Section 7 NEMS Validation Validation of the NEMS C9 Module is performed at the same time as validation of the AccuChrome GC Refer to Section 7 of the A...

Страница 20: ...ior of the unit Do not to submerse the unit in water clean it with a hose or with excessive amounts of water Do not attempt to clean any of the electronic equipment within the unit 8 3 Replacing Inter...

Отзывы: