background image

Legacy Series Combo

OWNER’S MANUAL

Part No: 160-1050-A

Part No: 160-1050-A

Содержание Legacy 112

Страница 1: ...Legacy Series Combo OWNER S MANUAL Part No 160 1050 A Part No 160 1050 A ...

Страница 2: ...our local dealer or GK as soon as possible For product registration visit gallien kruger com Gallien Krueger Inc 2234 Industrial Drive Stockton CA 95206 phone 209 234 7300 fax 209 234 8420 Internet www gallien krueger com Email info gallien com We wish you a lifetime of good playing and GK Philosophy I have never seen the point in doing things the way others have done them I also have not been ver...

Страница 3: ...email info gallien krueger com internet www gallien krueger com Warning This amplifier is capable of producing high sound pressure levels Continued exposure to high SPL s can cause damage to your hearing Always set the volume at a safe listening level or use hearing protection if the unit is operated at higher levels Table Of Contents Safety Instruction Safety Information Quick Start Tech Talk Fro...

Страница 4: ...lked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Attachments Only use attachments accessories specified by the manufacturer 12 Place Carefully Use only with the cart stand tripod bracket or table specified by the manufacturer or sold manufacturer or sold with with the apparatus the apparatus When a cart When is is used use caution...

Страница 5: ...ertain to use a standard IEC compliant cord Damaged power cords should be replaced immediately When setting up make certain that the AC plug is easily accessible If you do not intend to use the amplifier for a considerable length of time disconnect the plug from the AC mains socket Do not use an extension cord Earth Grounding Connection To prevent electric shock do not remove the grounding plug on...

Страница 6: ...on Connect your Instrument Using a shielded instrument cable connect your bass to the input jack and press the power switch to the on up position If you have active tone controls on your bass turn all of the controls to the middle or flat position and turn the volume all the way up If you have conventional passive tone controls turn all tone and volume controls all the way up Level and Master Volu...

Страница 7: ... mains power Pwr Illuminated when unit is powered on OT Indicates unit is experiencing a fault related to over temperature OC Indicates unit is experiencing a fault related to over current draw Clip Flashes when incoming signal exceeds the input circuit s capability Overdrive Engages Drive circuit when placed in the up position LED indicator is lit when Drive is enabled Edge Adjusts the high freq ...

Страница 8: ... 6 7 8 9 10 12 11 13 R C US AVIS RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR NE PAS EXPOSER A LHUMIDTE CONSULTER DU PERSONEL QUALIFE WARNING TO REDUCE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS INSTRUMENT TO RAIN OR MOISTURE DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL GERAT NICHT OFFEN NICHT IN FEUCHTER ODER NASSER UMGEBUNG BETREIBEN FUR...

Страница 9: ...ther equipment Moving the Unit Before moving the unit be certain to disconnect any cords connected to other components and make sure that you disconnect the unit from the AC outlet Cleaning When the unit gets dirty clean only with a dry cloth Never use benzene thinner alcohol or other volatile cleaning agents Do not use abrasive cleaners as they may damage the finish of metal parts Avoid spraying ...

Страница 10: ...n Maximum Input Level 0 6V rms Input Impedance 1M Ohms Direct Output Impedance 500 Ohms Aux in Input Impedance 100K Ohms Equalizer Bass 10dB 60Hz Lo Mid 6dB 10dB 250Hz Hi Mid 6dB 10dB 1KHz Treble 14dB 7KHz Voicing Filters Contour 2dB 50Hz 10dB 500Hz 3dB 7 KHz Noise Legacy 115 90 dB reference to 800W A weighted Legacy 112 90 dB reference to 800W A weighted Legacy 212 90 dB reference to 800W A weigh...

Отзывы: