50
●
BN
DMC-40x0 Command Reference
BN
FUNCTION:
Burn
DESCRIPTION:
The BN command saves controller parameters shown below in Flash EEPROM memory. This
command typically takes 1 second to execute and must not be interrupted. The controller
returns a : when the Burn is complete.
PARAMETERS SAVED DURING BURN:
AC CE GR MT SM
AF CN HV NB SP
AG CO IA NF TK
AQ CW IK NZ TL
AU DC IL OA TM
BA DH IT OE TR
BB DV KD OF VA
BI EO KI OP VD
BL ER KP OT VF
BM
FA KS OV VS
BO FL LC PF YA
BR FV LD PL YB
BW GA LZ PW YC
CB GM MO SB
USAGE: DEFAULTS:
While Moving
Yes
Default Value
-
In a Program
Yes
Default Format
-
Command Line
Yes
Controller Usage
ALL CONTROLLERS
OPERAND USAGE:
_BN contains the serial number of the controller.
RELATED COMMANDS:
Burn Program
Burn Variables
EXAMPLES:
KD 100
Set damping term for A axis
KP 10
Set proportional gain term for A axis
KI 1
Set integral gain term for A axis
AC 200000
Set acceleration
DC 150000
Set deceleration rate
SP 10000
Set speed
MT –1
Set motor type for A axis to be type ‘-1’, reversed
polarity servo motor
MO
Turn motor off
BN
Burn parameters; may take up to 5 seconds