DMC-40x0 Command Reference
AV • 39
AV
FUNCTION:
After Vector Distance
DESCRIPTION:
The AV command is a trippoint, which is used to hold up execution of the next command during
coordinated moves such as VP,CR or LI. This trippoint occurs when the path distance of a
sequence reaches the specified value. The distance is measured from the start of a
coordinated move sequence or from the last AV command. The units of the command are
quadrature counts.
ARGUMENTS:
AV s,t where
s and t are unsigned integers in the range 0 to 2147483647 decimal. 's' represents the vector
distance to be executed in the S coordinate system and 't' represents the vector distance to be
executed in the T coordinate system.
USAGE: DEFAULTS:
While Moving
Yes
Default Value
0
In a Program
Yes
Default Format
-
Command Line
No
Controller Usage
ALL CONTROLLERS
OPERAND USAGE:
_AVS contains the vector distance from the start of the sequence in the S coordinate system and
_AVT contains the vector distance from the start of the sequence in the T coordinate system.
EXAMPLES:
#MOVE
;
DP
0,0
;
'Label
CA
T
;
'Specify the T coordinate system
LM
AB
;
'Linear move for A,B
LI
1000,2000
;
'Specify distance
LI
2000,3000
;
'Specify distance
LE
BG
T
;
'Begin motion in the T coordinate system
AV
,500
;
'After path distance = 500,
MG
"Path>500"
;TP
AB
;
'Print Message
EN
;
'End Program
Hint: Vector Distance is calculated as the square root of the sum of the squared distance for each axis in
the linear or vector mode.