![Galil Motion Control DMC-40x0 Series Скачать руководство пользователя страница 222](http://html1.mh-extra.com/html/galil-motion-control/dmc-40x0-series/dmc-40x0-series_command-reference-manual_558773222.webp)
212
●
SA
DMC-40x0 Command Reference
SA
FUNCTION:
Send command
DESCRIPTION:
SA sends a command form one controller to another via Ethernet.
NOTE: A wait statement (e.g. WT5) must be inserted between successive calls to SA.
ARGUMENTS:
SAh=arg
or
SAh=arg, arg, arg, arg, arg, arg, arg, arg, where
h is the handle being used to send commands to the slave controller.
arg is a number, controller operand, variable, mathematical function, or string; The range for
numeric values is 4 bytes of integer (2
31
) followed by two bytes of fraction (+/-
2,147,483,647.9999). The maximum number of characters for a string is 38 characters.
Strings are identified by quotations.
Typical usage would have the first argument as a string such as “KI” and the subsequent
arguments as the arguments to the command: Example SAF=”KI”, 1, 2 would send the
command: KI1,2
USAGE: DEFAULTS:
While Moving
Yes
Default Value
-----
In a Program
Yes
Default Format
-----
Command Line
Yes
Controller Usage
ALL CONTROLLERS
OPERAND USAGE:
_SAhn gives the value of the response to the command sent with an SA command. The h value
represents the handle A thru H and the n value represents the specific field returned from the
controller (0-7). If the specific field is not used, the operand will be –2^31.
RELATED COMMAND:
Display messages
handle
EXAMPLES:
#A
IH
A
=10,0,0,12
;
'Configures handle A to be connected to a controller with
;
'the IP address 10.0.0.12
#B
;JP
#B
,_IHA2<>-2
;
'Wait for connection
SA
A
="KI", 1, 2
;
'Sends the command to handle A (slave controller): KI 1,2
WT
5
SA
A
="TE"
;
'Sends the command to handle A (slave controller): TE
WT
5
MG
_SAA0
;
'Display the content of the operand_SAA (first response to
;
'TE command)
: 132
--response from controller--
MG
_SAA1
;
'Display the content of the operand_SAA (2nd response to TE
;
'command)
: 12
--response from controller--
SA
A
="TEMP=",16
;
'Sets variable temp equal to 16 on handle A controller
EN
;
'End Program