142
●
KP
DMC-40x0 Command Reference
KP
FUNCTION:
Proportional Constant
DESCRIPTION:
KP designates the proportional constant in the controller filter. The filter transfer function is
D(z) = KP + KD(z-1)/z + KI z/2(z-1)
For further details see the section Theory of Operation in the User’s Manual.
ARGUMENTS:
KP n,n,n,n,n,n,n,n or
KPA=n where
n is an unsigned numbers in the range 0 to 1023.875 with a resolution of 1/8.
n = ? Returns the value of the proportional constant for the specified axis.
USAGE: DEFAULTS:
While Moving
Yes
Default Value
6
In a Program
Yes
Default Format
4.2
Command Line
Yes
Controller Usage
ALL CONTROLLERS
OPERAND USAGE:
_KPn contains the value of the proportional constant for the specified axis.
RELATED COMMANDS:
Constant
Integrator Constant
Integrator Limit
EXAMPLES:
KP 12,14,16,20
Specify a,b,c,d-axis proportional
KP 7
Specify a-axis only
KP ,,8
Specify c-axis only
KP ?,?,?,?
Return A,B,C,D
:7, 14, 8, 20
KP values
Note: KP now has four times more resolution as prior controllers, and thus the same value as that of an
Optima controller is four times less effective. KP1 with TE1 yields TT at 0.0003 Volts.