130
•
Chapter 9 Troubleshooting
DMC-1000
Communication
SYMPTOM CAUSE
REMEDY
Using COMDISK and
TALK2BUS, cannot communicate
with controller.
Address selection in
communication does not match
jumpers.
Check address jumper positions,
and change if necessary. The
addresses 1000 or 816 are
recommended. Note -- for address
1000, A2 and A4 jumpered. For
address 816, jumper A7, A6, A3,
A2.
Stability
SYMPTOM CAUSE REMEDY
Motor runs away when the loop is
closed.
Wrong feedback polarity.
Invert the polarity of the loop by
inverting the motor leads (brush type)
or the encoder.
Motor oscillates.
Too high gain or too little
damping.
Decrease KI and KP. Increase KD.
Operation
SYMPTOM CAUSE
REMEDY
Controller rejects command.
Responded with a ?
Invalid Command
Interrogate the cause with TC or
TC1.
Motor does not complete move.
Noise on limit switches stops the
motor.
To verify cause, check the stop
code (SC). If caused by limit
switch noise, reduce noise.
During a periodic operation, motor
drifts slowly.
Encoder noise
Interrogate the position
periodically. If controller states
that the position is the same at
different locations it implies
encoder noise. Reduce noise. Use
differential encoder inputs.
Same as above.
Programming error.
Avoid resetting position error at
end of move with SH command.