24
GALAXY 3000 GE MV VRD
EN
GALAXY 3000 GE MV VRD REF. 44000000
MD-1 REF. 44012058
M1
M2
M3
M1
M2
M3
Brand Symbol Description
of
use.
O
Panel connector 35/50 - Welding circuit connection. Negative pole.
P
Panel connector - Connection of remote control connector.
Q
Panel connector 35/50 - Welding circuit connection. Positive pole.
R
Cable - Power supply input.
S
O / I
Switch - Welding equipment start-up. ON / OFF
3.1.2. REMOTE CONTROL - MD1.
Brand
Symbol
Description of use.
Control potentiometer (Coarse mode) of the welding current value. It
incorporates a graduated dial on the rear of the device.
MAINS Min.
1 2 3 4 5 6 7 8 9
Max.
3
Ph 12 15 55 100 125 150 175 205 240 285 300
M1
1
Ph 12 15 45 70 90 105 120 140 160 190 200
M2
Welding current control potentiometer.
Control: FINE mode +5A ÷ -5A
M3
----
Remote control connector. You must connect this to the "P" connector of
machine front panel.
The remote control connection will be carried out through connector “P” situated on the front of the
equipment.
The equipment will automatically recognise the remote control connection “M3", and LED "F" will light up,
leaving the encoder "G" disenabled.
During the “Remote” working mode, the display “L” will maintain the regulation process from the remote
control encoders “M1 and M2”. To enable control “G” again, just disconnect remote control “M3”, and the
LED “F” will go out.