Q. The audio quality that can be heard on the remote telephone is poor or humming 

(buzzing).

A. A small amount of GSM buzz can be considered normal on 3G audio intercoms, but not so much 

that  causes  inability  to  hear  the  person  speaking.  This  can  be  caused  by  the  GSM  antenna  being 

mounted too close to the speech panel or not mounted high enough.

-Try earthling the speech panel chassis to 0V of the power supply.

-This is also a symptom of poor reception. Try above steps on checking and improving reception.

Q. The 1 or 2 key does not work when the intercom calls a phone.

A. Check if you can hear the relay clicking at the gate when the 1 or 2 key is pressed during a call. 

If it can be heard, then the system is working, check wiring between the relay and the lock or gate 

panel. If the relays do not make a clicking sound, then check this feature on a different mobile cell 

phone  or  landline.  If  it  works  on  a  different  phone,  check  the  settings  on  the  phone  in  question 

under DTMF tones. Failure of DTMF tones to operate correctly is also a symptom of low reception. 

Check  steps  above  on  improving  reception.  Try  pressing  the  buttons  longer  when  attempting  to 

activate the gates or door.

SPECIFICATION:

Model

SS1603-08 3G Audio Intercom

GSM / WCDMA Frequency 

GSM 850/900/1800/1900 Mhz, WCDMA 800/850/900/1900/2100 Mhz

Outputs

2 outputs, NC/NO dry contact, 10A/240V AC / 24V DC

Power supply 

12~24V AC/ DC ( 12V DC/ 1.5A power supply adaptor included)

Power Consumption 

Standby:48~68mA/ hr, Using: 100~135mA/hr 

Surface back box size

189 (H) x 118 (W) x 65(D) mm

Face plate size

180 (H) x 109 (W) mm 

Design and material 

Vandal resistant / die cast aluminum 

Length of antenna 

3 meters cable 

Humidity 

Less than 80% RH

Operating Temperature 

-20

to 50

Operating Current 

Maximum 250 mA, Typically 55mA 

Содержание SS1603-08

Страница 1: ...3G Audio Intercom E5 07262019 1 GAINWISE TECHNOLOGY MANUAL DOORINTERCOM SS1603 08 3G AUDIO INTERCOM ACCESS CONTROL SYSTEM For your protection read these instructions completely And keep them for future reference ...

Страница 2: ... INTERCOM OPERATION 9 Enter Listener Monitoring Mode 11 Enter Access Control Mode 11 Enter Programming Mode 11 Programming 12 Access Control Options 13 Check 3G Signal Strength 15 Check Relay Detect Status 15 Administrator Number 15 CHECK ALL LOGGED DOOR ACCESS EVENTS VIA E MAIL OR SMS 16 USER COMMANDS 19 HOW TO RESET THE HARDWARE WHEN YOU FORGET YOUR PASSWORD 24 HOW TO CHANGE THE NAME PLATE 25 QU...

Страница 3: ... the product 2 Unplug all the connections of product before cleaning Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning 3 Do not use this product near water 4 Do not use this product near an area where there is a potential of gas leaks or near any fumes that can be explosive 5 Do not place this equipment near or over a radiator or any other heat source 6 Do not overload t...

Страница 4: ...d number held within the unit to open your gates when a call is received it is dropped and the Caller ID checked against numbers programmed and if there is a match will send a signal to open any unknown callers will be ignored The unit is easily wired into your gate and garage systems and it does not need any special installation or complicated wiring it needs power only and an active SIM card Pro...

Страница 5: ...tercom E5 07262019 5 SS1603 08 3G AUDIO INTERCOM WITH ACCESSORIES Item Description Q ty 1 SS1603 08 3G audio intercom 1 2 Power adapter 1 3 External 3 meter antenna 1 4 Mounting Bracket for antenna 1 5 Operational manual 1 ...

Страница 6: ...SS1603 08 3G Audio Intercom E5 07262019 6 INSTALLATION This 3G audio intercom is suitable for both flush and surface mounting SS1603 08 3GAUDIO INTERCOM UNIT Call Button Speaker Microphone ...

Страница 7: ...SS1603 08 3G Audio Intercom E5 07262019 7 Wiring Diagram ...

Страница 8: ...on a mobile phone 2 Check that the SIM does not have a PIN code request 3 Disable voicemail service on the SIM 4 Power should be OFF before inserting the SIM 2 Antenna Install the antenna as high as possible on the top of the pillar for best possible reception 3 Door Lock Connect an electric door lock to terminals marked door latch 4 Power Supply Connect a 12 volt DC power supply to terminals mark...

Страница 9: ...trol mode 3 Programming mode To gain access to the system menu via dial in follows these steps 1 Call the telephone number of the 3G audio intercom 2 Wait for the intercom to answer and signal by one beep to enter system menu 3 Enter the password of the mode you would like to enter 4 Password correct one beep password error 3 beeps 5 3 times failure attempt on password hang up the call ...

Страница 10: ...SS1603 08 3G Audio Intercom E5 07262019 10 ...

Страница 11: ...predefined numbers 3 You will hear a Do tone to enter access control mode by pressing 33 5678 where 5678 is the password 4 The door will be opened after enter the correct password To open the door by password if the number is not stored in the access control section Enter Programming Mode 1 Call the telephone number of the 3G audio intercom 2 This device will then verify your phone number with you...

Страница 12: ...t with the pass code default 1234 in the following format 12 1234 Followed immediately by a command 4 To program a call button numbers DO NOT enter country code just the complete number as you would dial it Example Storing a call button phone numbers Max 3 numbers and delete 2 3 phone numbers 058 57235 landline number 1 086 5682554 mobile number 2 086 2235644 mobile number 3 SMS format storing a c...

Страница 13: ...pt will produce 3 short bleeps You may now program up to 1150 telephone numbers into memory Use the following commands to program the unit Insert international country code 1 3 digits 71 country code Add a number up to 1150 numbers 72 relay telephone number Delete a number 73 telephone number Delete all numbers 73 ACCESS CONTROL OPTIONS 1 Caller ID recognition 2 Enter password code by call or send...

Страница 14: ... delete phone numbers of dialing in to open SMS format to delete phone number 1 and 2 12 1234 730865683624 730865682554 SMS format to delete all numbers 12 1234 73 2 Enter password codes by call or send SMS If your number is not saved in the intercom memory it will answer the call Enter the Password code on your telephone keypad or just send a SMS to activate the door or gate 33 5678 trigger relay...

Страница 15: ... detect status SMS format 22 SMS Reply Relay1 release Relay2 hold Detect ON IN1 ON Remark Terminal mark Detect see wiring diagram is for you to connect a door reed switch The gates would have a reed switch wired through the DET input to ground It s used by the user to check if the gates are open or closed Administrator Number Once the administrator number is stored the unit will only accept progra...

Страница 16: ... 0 sending when it reaches 100 events default N 1 sending when it reaches 200 events max Sending record when it reaches 200 events command code example 12 1234 831 2 Sending logged events via e mail 12 1234 84 N N 0 no saving sending events N 1 via SMS 4 events limited per SMS N 2 via E mail Sending logged events via email command code example 12 1234 842 3 GPRS parameters setting 40 1234 APN auth...

Страница 17: ...ing 4 N 1234 N 0 reply GPRS parameters N 1 reply e mail parameters N 2 reply recipient carbon copy N 3 reply e mail subject Check GPRS parameters setting Command code example 40 1234 9 Mobile number for receiving logged events via SMS 12 1234 85 mobile number 10 Delete mobile number for receiving logged events via SMS 12 1234 85 11 Clock Sync auto time calibration after power fail 12 1234 86 SIM p...

Страница 18: ...ogram many different user command codes in a single text message with SMS command format 12 1234 command Code1 command Code 2 command Code3 Example Mobile number for receiving logged events 0907967223 SIM phone number held within the unit 0948778458 12 1234 841 850907967223 860948778458 Send 44 1234 to check logged events Log format ...

Страница 19: ...he surroundings where the intercom installed 1212 3 Enter Access control Mode Trigger relay 1 33 password Password mode access option 5678 4 Hold Relay 1 34 password To hold relay to keep door opened 5678 5 Release Relay 1 35 password To release relay for door close 5678 6 Trigger relay 2 36 password Password mode access option 5678 7 Hold Relay 2 37 password To hold relay to keep door opened 5678...

Страница 20: ...etect Input IN1 Input Status hold release trigger Input on off 4 Check detect SMS content 26 1234 Default PWD 1234 Detect PIN Trigger 5 Check intercom move detection SMS content 27 1234 Default PWD 1234 Case open 6 Check power loss SMS content 28 1234 Default PWD 1234 Power loss 7 Check power active SMS content 29 1234 Default PWD 1234 Power active 8 Check input 1 triggered SMS content 30 1234 Def...

Страница 21: ...Speaker Volume 3 speaker volume speaker volume level 0 4 3 7 Microphone Volume 4 microphone volume microphone volume level 0 4 3 8 Relay 1 Time 51 relay 1 time relay time 1 9999 sec 1 9 Relay 2 Time 50 relay 2 time relay time 1 9999 sec 1 10 Ringing time on call out numbers 52 ringing time divert time 10 99 sec Adjust this to avoid voice mail picking up a call 20 sec 11 Max talk Time 53 max talk t...

Страница 22: ...e administrator phone number None 21 Disable enable SMS reply notice 894 X X 0 disable X 1 enable Disable enable SMS replay Relay 1 trigger relay 2 trigger Relay 1 hold relay 2 hold Relay 1 release relay 2 release 0 22 Dial tone volume 898 X X 1 3 levels 2 23 Engress for push to exit button 900 X X 0 relay 1 X 1 relay2 0 24 Detect for engress mode 901 X X 0 relay 1 X 1 relay2 1 25 Detect mode opti...

Страница 23: ... 1 is trigged SMS content 30 password SMS content PWD default 1234 SMS content 100 characters IN1 trigger 34 Change relay1 and 2 trigger hold release codes 93 Y ABCDEF Y call button 01 08 ABCDEF 0 9 and single digit A trigger relay 1 default 1 B hold relay 1 default 2 C release relay 1 default 3 D trigger relay 2 default 4 E hold relay 2 default 5 F release relay 2 default 6 N A 35 Change all rela...

Страница 24: ...udio Intercom E5 07262019 24 HOW TO RESET THE HARDWARE WHEN YOU FORGET YOUR PASSWORD 1 Keep both reset and engress buttons pressed 2 Release all buttons after you hearing continuous Dou tones 3 Hardware reset is done ...

Страница 25: ...SS1603 08 3G Audio Intercom E5 07262019 25 HOW TO CHANGE THE NAME PLATE ...

Страница 26: ...try code 72 relay phone number 72 relay phone number 72 relay phone number Example Ireland Country code 353 UK 44 USA 1 Do not use any leading zeroes 086 5683624 mobile number 1 086 5682554 mobile number 2 086 2235644 mobile number 3 SMS format 12 1234 71353 7210865683624 7210865682554 7220862235644 Operation When intercom is calling your phone and once you answer the phone and speak to your visit...

Страница 27: ...ally inspect that the centre pin inside the antenna is intact and has not been pushed back inside the fitting Q The unit calls the first number but there is not enough time to answer before it diverts to the next number A Increase the no answer time as per programming instructions Q The unit calls the first number but voicemail comes on before it can ring the second number A Decrease the no answer...

Страница 28: ...k or gate panel If the relays do not make a clicking sound then check this feature on a different mobile cell phone or landline If it works on a different phone check the settings on the phone in question under DTMF tones Failure of DTMF tones to operate correctly is also a symptom of low reception Check steps above on improving reception Try pressing the buttons longer when attempting to activate...

Отзывы: