background image

   NOTE: 

• Carefully follow these instructions when installing as the process differs from other Gainsborough products. 
• Do not overtighten screws. 
• Use of power driver is not recommended. 
• Screws to be tightened to a recommended 2.5Nm torque. 
• Fully remove the G+ Lockset prior to painting the door to avoid harming the product’s finish.

G+ LOCKSET: ELECTriC

 

installation instructions for  
the Apex and Volt Electric Locksets

G+ ACCESS SYSTEM

1 X G+ LOCKSET

SCREW KIT A

SCREW KIT B

SCREW KIT C

SCREW KIT D

WhaT’S IN yOUr G+ LOCKSET BOX?

FOLD HERE

CENTRELINE

LATCH

Latch height

Power transfer
unit heights

CAUTION

Hole drilling sequence 

as per instructions

Please refer to G+ 
Lockset Installation 
Manual for 
Instructions on how 
to use this template

Paper size A3. 
These dimensions 
are for reference 
only to ensure that 
scale is correct.

FOLD HERE

G+ LOCKSET 

APEX

Installation Template for Door Face
Use for Battery and Electric Locksets

G+ ACCESS SYSTEM

54mm

10mm

10mm

10mm

10mm

10mm

10mm

10mm

54mm

54mm

BACKSET 60MM

BACKSET 60MM

FIT HERE ON

DOOR EDGE

G+ ACCESS SYSTEM

Lever height

Strike height

Power Transfer Unit height

G+ LOCKSET 

ELECTRIC

Installation Template for Door Frame

G+ LOCKSET 

ELECTRIC

Installation Template for Door Frame

7

5mm

Please refer to G+ Lockset 
Installation Manual for Instructions 
on how to use this template

Paper size A4. These dimensions 
are for reference only to ensure that 
scale is correct.

FOLD HERE

FOLD HERE

CENTRELINE

LATCH

Latch height

10mm

54mm

54mm

G+ LOCKSET 

VOLT

Installation Template for Door Face
Use for Battery and Electric Locksets

CAUTION

Hole drilling sequence 

as per instructions

Power transfer
unit heights

Please refer to G+ 
Lockset Installation 
Manual for 
Instructions on how 
to use this template

Paper size A3. 
These dimensions 
are for reference 
only to ensure that 
scale is correct.

G+ ACCESS SYSTEM

FIT HERE ON

DOOR EDGE

10mm

10mm

10mm

10mm

10mm

54mm

10mm

BACKSET 60MM

BACKSET 60MM

APEX DOOR TEMPLATE

FRAME TEMPLATE:  

ELECTRIC

VOLT DOOR TEMPLATE

Or

A

C

B

D

Содержание G+ LOCKSET

Страница 1: ...ery and Electric Locksets G ACCESS SYSTEM 54mm 10mm 10mm 10mm 10mm 10mm 10mm 10mm 54mm 54mm BACKSET 60MM BACKSET 60MM FIT HERE ON DOOR EDGE G ACCESS SYSTEM Lever height Strike height Power Transfer Unit height G LOCKSET ELECTRIC Installation Template for Door Frame G LOCKSET ELECTRIC Installation Template for Door Frame 75mm Please refer to G Lockset Installation Manual for Instructions on how to ...

Страница 2: ...ight mark you made in the previous step Firmly hold the template and mark the 2 Power Transfer Unit heights top markings and the 2 Strike heights bottom markings on the frame Remove the template and measure the door thickness Divide this size in half and measure this size from the jam Take note of any weather strips that may be fitted to the door jam Mark this position on the 2 Power Transfer Unit...

Страница 3: ... from the In line Power Unit This will be in the door frame cavity Pull the end of the wire out through the top hole in the door frame Connect the Power Transfer Unit to the wire from the In line Power Unit Insert the Power Transfer Unit into the door frame As you do this carefully guide the excess wire back into the door frame cavity Fix using 2 black wood screws from KIT D Insert the strike and ...

Страница 4: ...ecess of 4mm for the Battery Box faceplate So that Battery Box faceplate is flush with the door edge Use the Battery Box as a template Mark and chisel a recess of 4mm for the latch faceplate So that the latch faceplate is flush with frame the door edge Use the latch as a template Insert the latch making sure that the tapered bevelled side of the latch faces towards the door frame when the door is ...

Страница 5: ... Assemble the Battery Box transmitter and fix using 2 black wood screws from KIT D 10 11 NOTE Do not over tighten these screws Do not use power tools IMPORTANT NOTICE NiMH batteries MUST be used in this product Failure to do so could result in severe damage and will void any warranties Switch A Shift selection Switch B Revert to privacy 12 Install 6 posts from KIT B onto the outside faceplate Tigh...

Страница 6: ...wise Leave key in this position Assemble the connector from the Battery Box with the connector on the faceplate Make sure they are firmly pressed together Hold the faceplate flush against the door face making sure that wires from the Battery Box are not trapped The key can now be turned back to the vertical position and removed The faceplate is now temporarily secured and will not fall if let go F...

Страница 7: ...first G Key to be taught press buttons 4 5 diagram 17 These buttons must be pressed simultaneously until the lockset emits a single beep 3 Repeat step 2 for each G Key to be taught Each additional G Key must be added within the 10 seconds otherwise the lockset will time out and replace any previously taught G Keys with the keys taught in this session 4 Once the last G Key has been taught wait for ...

Страница 8: ...aranteed and Gainsborough Hardware reserves the right to alter amend or delete any part of this document without prior notice This disclaimer is subject to any contrary legislative provisions Take care electricity kills Switches power outlets and other fixed wire products must be installed by a licensed electrical contractor or similarly qualified person Gainsborough Hardware Industries Limited Ho...