300 Series Emergency Telephone 

Manual 

T

A B L E   O F  

C

O N T E N T S

 

Confidentiality Notice .....................................................................................................................1

 

Product Overview ............................................................................................................................1

 

Telephones ............................................................................................................................................... 1

 

Telephone Management Application (TMA) ....................................................................................... 5

 

Standard Operation .........................................................................................................................6

 

Emergency Call Operation ..................................................................................................................... 6

 

Non-Emergency Call Operation ............................................................................................................ 6

 

Non-Emergency Assistance Operation (Model 396-00x) .....................................................................  7

 

Receiving a Call ....................................................................................................................................... 7

 

Disconnecting a Call ............................................................................................................................... 7

 

Location Identification Code Dialing .................................................................................................... 7

 

Installation ......................................................................................................................................8

 

Safety Guidelines ..................................................................................................................................... 8

 

General Installation Guidelines ............................................................................................................. 9

 

Security Hardware .................................................................................................................................. 9

 

Conduit Installation Details ................................................................................................................... 9

 

Models 393-00x, 393AL-00x, and 394AL-00x .....................................................................................  11

 

Models 397-00x, 396-00x, 398-00x and 392-001 ................................................................................. 13

 

Stanchion or Flush-Mount Applications ............................................................................................................. 13

 

Retro-fit Models .................................................................................................................................... 16

 

External Power for -003 and -004 Models .......................................................................................... 20

 

Connecting a Model 530 Series Strobe ................................................................................................ 20

 

Setup ..............................................................................................................................................21

 

Hardware Configuration ...................................................................................................................... 21

 

Auto-answer Configuration ................................................................................................................................ 21

 

Polarity Configuration ........................................................................................................................................ 21

 

DTMF Gain Select Configuration ....................................................................................................................... 21

 

Содержание Red Alert 300 Series

Страница 1: ...all Operation 6 Non Emergency Call Operation 6 Non Emergency Assistance Operation Model 396 00x 7 Receiving a Call 7 Disconnecting a Call 7 Location Identification Code Dialing 7 Installation 8 Safety...

Страница 2: ...Annunciation Activation 27 Auxiliary Output Control 28 Standard Mode Programming 30 Set up Sequence 30 Remote 30 Local 30 Programming Sequence 31 Password Disabled Programming 31 Programming Sequences...

Страница 3: ...you know when it is experiencing problems When used with our TMA Telephone Management Application software RED ALERT telephones will reduce system test and maintenance time while greatly decreasing li...

Страница 4: ...E Connection to pay telephone extensions or shared service party lines should be avoided Each telephone requires a minimum line current of 24 mA for proper operation For operation below 4 F 20 C GAI T...

Страница 5: ...hole includes a HELP autodial push button 397 00xRT Flush Mount Emergency Telephone with a heavy gauge brushed stainless steel front panel designed to retrofit a Ramtel flush mount telephone six hole...

Страница 6: ...or CALL if equipped push buttons All RED ALERT Telephones are ordered for standard operation no options by using a 001 suffix example 393 001 or 397 001CB Telephones with factory installed options ar...

Страница 7: ...e very important in larger systems A TMA expansion kit Model 12509 036 is available and is required for each additional connected telephone line with a maximum of eight lines allowed This allows a max...

Страница 8: ...ndicator will begin to flash when the HELP push button is pressed and will light steadily when the telephone detects audio after the call is answered or The indicator will begin to flash when the HELP...

Страница 9: ...owing Remote disconnect of an emergency call Called party transmits either a or 99 DTMF control command Manual disconnect of an emergency call Press the HELP push button approximately 15 seconds after...

Страница 10: ...National Electrical Code NEC Grounding has to be ensured for safe and stable communications Do not use long and coiled ground wires Trim ground wires to the required length Use a star configuration w...

Страница 11: ...will depend on the line current the length of the cable run and the condition of the telephone cable NOTE A RED ALERT Telephone should never be installed on the same telephone line as any other non RE...

Страница 12: ...elow for the recommended conduit installation details Figure 1 Bottom entry conduit recommended for non metallic enclosures Figure 2 Top entry conduit installation for non metallic enclosures NOT reco...

Страница 13: ...ed Refer to conduit installation details on page 10 NOTE Use silicone sealant or equivalent around and inside all conduit entries 5 Pull the telephone line through the conduit and into the enclosure C...

Страница 14: ...ERGENCY TELEPHONE MANUAL PAGE 12 of 45 f standard ioms current release 42004 instr manuals 42004 438k doc 01 15 Figure 6 Model 393AL 00x Figure 7 Model 394AL 00x Figure 8 Model 393 00x 393AL 00x and 3...

Страница 15: ...s Stanchion or for flush mount installations the supplied back box must be used to mount the Model 397 00x 396 00x 398 00x or 392 001 Telephone Mount the back box to the structure using appropriate ha...

Страница 16: ...or An inline coupler is provided for use if necessary Refer to Figure 13 Model 397 00x 396 00x 398 00x and 392 001 Mounting Details for the Model 397 00x 396 00x 398 00x and 392 001 component location...

Страница 17: ...42004 438K 300 SERIES EMERGENCY TELEPHONE MANUAL PAGE 15 of 45 f standard ioms current release 42004 instr manuals 42004 438k doc 01 15 Figure 13 Model 397 00x 396 00x 398 00x and 392 001 Mounting Det...

Страница 18: ...use if necessary Plug the connector into the mating connector inside the enclosure 5 Allow the telephone a minimum of 35 seconds to initialize 6 Using the Setup section of this manual Configure the h...

Страница 19: ...IES EMERGENCY TELEPHONE MANUAL PAGE 17 of 45 f standard ioms current release 42004 instr manuals 42004 438k doc 01 15 Figure 16 Model 397 00xRT Figure 17 Model 398 00xRT Figure 18 Model 397 00xTP Figu...

Страница 20: ...PUB 42004 438K 300 SERIES EMERGENCY TELEPHONE MANUAL PAGE 18 of 45 f standard ioms current release 42004 instr manuals 42004 438k doc 01 15 Figure 20 Back Box for Ramtel RT and Code Blue CB...

Страница 21: ...PUB 42004 438K 300 SERIES EMERGENCY TELEPHONE MANUAL PAGE 19 of 45 f standard ioms current release 42004 instr manuals 42004 438k doc 01 15 Figure 21 Back Box for Talk A Phone TP...

Страница 22: ...on the telephone PCBA Remove the jumper from P17 pins 3 and 4 and insert to the adjacent header J18 when using the plug in power supply See Figure 23 on page 23 for jumper locations NOTE The external...

Страница 23: ...umper in position EN Disable J14 jumper in position DIS Do not use this setting except under the direction of GAI Tronics personnel NOTE The Auto answer feature must be enabled to allow the GAI Tronic...

Страница 24: ...r in position STD Low PowerModeConfiguration Factory Setting Low Power Mode Disabled For some installations in which only minimal loop current is available the performance of the telephone may be impr...

Страница 25: ...ed solid state switches capable of switching a maximum of 48 V dc 125 mA or 28 VRMS ac 80RMS mA TB2 OUT1 and TB5 OUT4 on the emergency telephone PCBA provides the connections for the auxiliary outputs...

Страница 26: ...power supply is a connectorized 4 foot power cable that plugs into P17 on the telephone PCBA P17 must be vacated prior to plugging in the power supply To do so remove the jumper from P17 pins 3 and 4...

Страница 27: ...he Voice Annunciation PCBA Position yourself approximately 12 inches from the microphone in front of cover To begin recording momentarily press the record push button After hearing a short beep begin...

Страница 28: ...er the 75 sequence again 4 Position yourself approximately 12 inches from the microphone in front of cover and begin speaking in a conversation level voice Maximum message duration is two minutes 5 Pr...

Страница 29: ...ss 8321 and after hearing a short beep begin speaking 6 Press when recording has been completed 7 The recording will automatically play back when the DTMF code is pressed VoiceAnnunciationActivation S...

Страница 30: ...a GAI Tronics 530 Series Strobe NOTE Output 1 can be programmed to remain closed for up to 255 minutes in 1 minute increments after the emergency call ends This output extension can be deactivated vi...

Страница 31: ...ct to close for a pre programmed amount of time then release The RED ALERT Telephone will acknowledge acceptance of this deactivation command with a short beep If the beep is not initially received re...

Страница 32: ...in Table 13 on page 40 Set up Sequence Set up each RED ALERT Emergency Telephone for either remote access programming or for local access programming keypad required Remote Using a touch tone telephon...

Страница 33: ...cally time out and disconnect if 20 seconds elapses between digit entries or if an invalid password is entered 2 If DTMF digits have not been dialed within 3 seconds of the first success tone the tele...

Страница 34: ...s sequence will continue until the emergency call is answered or all numbers have been attempted one attempt each When operating in SMART mode the number of attempts to call each programmed number can...

Страница 35: ...xcept the sequence ends in 2 instead of 1 None HELP Button Auto dial Number 3 DD 3 Same as HELP Button Auto dial Number 1 except the sequence ends in 3 instead of 1 None CALL or ASSISTANCE Button Auto...

Страница 36: ...d Programming Feature Key Sequence Description Default Password Protection 1 4 N N N N A four digit password must be supplied to remotely program the telephone If you change the password and cannot en...

Страница 37: ...Off Hook Ringing Feature Key Sequence Description Default Off Hook Ringing 2 2 L Enabling the Off Hook Ringing feature allows a person to call the telephone and have the telephone function as a norma...

Страница 38: ...l Time out Disconnect Option 1 2 N N This feature programs the maximum length of a call if no other disconnect features are used The valid entries are 1 99 representing 1 minute increments and 0 repre...

Страница 39: ...tup 1 3 L N N N This option enables and stores the three digit location identification ID number To enable the ID feature set L 1 To disable the ID feature L 0 Enter the three digit location identific...

Страница 40: ...Output 4 can be set in the range of 0 1 to 12 7 seconds in 0 1 second increments Table 11 Output 4 Control Options Feature Key Sequence Description Default Control Sequence N N 8 Assigns the digits N...

Страница 41: ...sequence If enabled Early Microphone operation will occur for both emergency and non emergency call operation of the Model 398 001 and 394AL 001 Telephones Use of the Early Microphone feature include...

Страница 42: ...ture Programming see Table 5 on page 34 Password Protection 14NNNN 2468 Disconnect Options Programming see Table 8 on page 36 Emergency Push button Disconnect 17L 1 enabled Call Time out Disconnect 12...

Страница 43: ...a written explanation of all defects to assist our technicians in their troubleshooting efforts Call 800 492 1212 inside the USA or 610 777 1374 outside the USA for help identifying the Regional Servi...

Страница 44: ...d solid state switch 48 V dc 125 mA 28 VRMS ac 80 mARMS Signaling DTMF 100 ms tone Memory Non volatile EEPROM Mechanical Operating temperature range 003 and 004 Models 40 F to 140 F 40 C to 60 C 001 a...

Страница 45: ...398 00x 7 2 lbs 3 3 kg Model 392 001 7 2 lbs 3 3 kg Code Blue Retrofit Phones Dimensions 11 75 8 50 2 68 inches 298 5 215 9 68 1 mm Weight Model 397 00xCB 6 0 lbs 2 7 kg Model 398 00xCB 6 7 lbs 3 0 k...

Страница 46: ...BA Keypad Assembly 51035 019 PCBA Keypad Assembly 12542 002 Security Screws Torx T 25 inch Pack of 15 12516 003 Security Screws Torx T 25 1 inches Pack of 10 12520 009 Push Button Replacement Kit HELP...

Страница 47: ...e local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not prevent...

Страница 48: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...