GAI-Tronics 370-901 Скачать руководство пользователя страница 17

Pub. 42004-525A 

Model 370-901 SP2 to Page/Party

®

 Bridge 

Page 15 of 16 

P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-525A.docx 
08/18 

Import Saved Configuration 

  Click the 

I

MPORT 

S

AVED 

C

ONFIGURATION

 button to load a saved configuration to the bridge. 

N

OTE

:

  Only designated values that are not device specific are imported. 

A standard Windows

®

 

O

PEN

 dialog box opens.  Browse to the desired folder and open the desired 

configuration file.  Click the 

U

PDATE

 button for the imported configuration to take effect. 

GUDA Software Updates 

Click OK to install updates to the GUDA software when the 

U

PDATE 

A

VAILABLE

 box appears after 

launching the GUDA application.  Updates are made available for automatic download and installation 
upon launching the GUDA. 

 

Troubleshooting 

Problem 

Solution 

Any problem with station 
performance 

Always review all steps of installation, ensuring that you 
correctly followed 

all

 steps.  Check all terminations on the 

board and in the Line Balance Assembly before proceeding to 
any other adjustments. 

Crosstalk 

One or more system cable pairs may be improperly terminated.  
Visually inspect the system cable for accidental crossing of 
cable pairs or grounds. 

 

Содержание 370-901

Страница 1: ...losure 2 Mount the Enclosure 3 Field Terminations 3 Earth Ground 3 Ethernet TB1 4 Page Party 33 Ohm Audio Connections P2 5 60029 Series Page Party System Cable 5 Channel Isolation Inputs P3 6 Contact...

Страница 2: ...A 19605 USA 610 777 1374 800 492 1212 Fax 610 796 5954 VISIT WWW GAI TRONICS COM FOR PRODUCT LITERATURE AND MANUALS GUDA Software Updates 15 Troubleshooting 15 Service and Spare Parts 16 Specification...

Страница 3: ...n may only be used in connection with the operation of your GAI TRONICS product or system This manual may not be disclosed in any form in whole or in part directly or indirectly to any third party Gen...

Страница 4: ...Adhere to all warnings on the unit and in the operating instructions Attachments Attachments not recommended by the product manufacturer should not be used as they may cause hazards Open the Enclosure...

Страница 5: ...unting holes are 0 280 inches in diameter 4 Install conduit using Myers ST 4 1 25 inch Scru Tite hubs or equivalent Reducers must be used for smaller conduit sizes to ensure proper contact with the su...

Страница 6: ...Install ferrules onto the wire ends 3 Connect the Ethernet cable to the 8 position pluggable terminal block TB1 see Figure 4 and Table 1 4 Connect the pluggable terminal block to terminal block recept...

Страница 7: ...y SystemCable Page Party stations should be connected using GAI TRONICS 60029 Series system cable Refer to Table 3 for the Page Party system cable color codes Table 3 Page Party 60029 Series System Ca...

Страница 8: ...re terminated at terminal block P4 P4 is an 18 position terminal block Three position pluggable terminal blocks are used for each output to simplify the connection of the outputs 1 Pull the cable s fo...

Страница 9: ...es onto the wire ends 3 Connect the line and neutral conductors to the pluggable terminal block see Figure 4 and Table 6 4 Connect the pluggable terminal block to terminal block P1 Close the Enclosure...

Страница 10: ...m the GUDA screen 4 Double click the SP2 TO PAGE PARTY BRIDGE to configure from the list of devices displayed Bridges that are not configured appear as follows 5 Enter the default user name shown and...

Страница 11: ...emory address of the control service IP Address client network address leave blank for DHCP clients Netmask subnet mask leave blank for DHCP clients Default Gateway IP address of router to other netwo...

Страница 12: ...Multicast Port multicast service port address for the audio channel Multicast TTL time to live for multicast network traffic Analog VOX Threshold mV signal voltage where the VOX circuit picks up 1 10...

Страница 13: ...TATUS screen provides the following information Firmware Version bridge firmware version IP Address IP address currently assigned to the bridge MAC Address MAC address of the bridge Network Data Rate...

Страница 14: ...streams passing through the bridge Operation The SP2 to Page Party Bridge provides real time audio communication between SP2 and Page Party systems No user interaction is required after the bridge is...

Страница 15: ...s are not disconnected with a pause in conversation Table 7 System Status LEDs LED State Description PL1 On activity on party line one PL2 On activity on party line two PL3 On activity on party line t...

Страница 16: ...tandard Windows OPEN dialog box Browse to the desired folder and open the desired firmware file and then click BEGIN UPDATE in the DEVICE FIRMWARE UPDATE box to update the devices firmware Enable Disa...

Страница 17: ...guration to take effect GUDA Software Updates Click OK to install updates to the GUDA software when the UPDATE AVAILABLE box appears after launching the GUDA application Updates are made available for...

Страница 18: ...50 60 Hz Ethernet 100Base TX 1000Base T with IGMP Output relay contact rating 1 A 30 V dc Channel isolation inputs dry contact Ethernet Cable Category 5 or better Speed 100 Mbps minimum Maximum stati...

Страница 19: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Отзывы: