44
English
2
Make sure that the yellow locking hook of the brew group is in the correct
position.
To position the hook correctly, push it upwards to the highest possible position.
If the hook is still in a lower position, this means that it has not been correctly
positioned.
3
Reinsert the brew group into the machine along the side guides until it locks in
position with a click.
Warning
: do not press the PUSH lever.
4
Insert the internal drip tray and the coffee pucks container.
5
Close the service door.
Lubricating the brew group
To ensure the perfect performance of the machine, it is necessary to lubrificate the
brew group. Refer to the following table for the frequency of lubrification.
Frequency of use
Number of daily brewed
beverages
Lubrication
frequency
Low
1-5
Every 4 months
Regular
6-10
Every 2 months
High
>10
Monthly
1
Turn off the appliance and unplug the power cord.
2
Remove the brew group and rinse it with lukewarm water (see chapter "Brew
group cleaning under fresh water").
3
Apply a thin layer of the supplied lubricant around the insertion pin located at
the bottom of the brew group.