12
Technical data (gas)
Burners: super strong burner
Level 1 low flame
< 850 BTU (0.25 kW)
Level 2 full inner flame
< 1 700 BTU (0.50 kW)
Level 3 small outer flame
plus level 2 full inner flame3 500 BTU (1.50 kW)
Level 4 full flame
17 000 BTU (5.00 kW)
Gas connection:
R 1/2’’ union nut for R 1/2’’ bracket to DIN 1999,
conical-cylindrical
Technical data, gas
Technical data (electrical)
Rated consumption
0.8 W
Voltage
AC 120 V
Frequency
60 Hz
Technical modifications reserved.
6. Technical data / Table
Countries
USUS
CA
CA
Gas family
Natural gas
Propane gas
Gas type
N
X
Pressure
6” W.C. (1.5 kPa)
10” W.C. (2.5 kPa)
Outer burner, full
170 B
1.10
Outer burner Bypass
0.79
0.57
Inner burner, full
Nr. 44
Nr. 3
Inner burner Bypass
0.44
0.31
Air gap adj / outer [mm]
2
0
Air gap adj / inner
1
/
2
open
open
∑ Power
17 000 BTU (5 kW)
17 000 BTU (5 kW)
∑ Consumption
0.48 m
3
/h
364 g/h