142_58300000122107_ara_en_b.doc – 02.02.09
Seite 11 von 16
At the outputs L1, L2 for the blower only 0 or 230V can be measured
against N.
The individual speeds are generated by upstream capacitors and
resistors. See table
Output L1
Output L2
Circuit
Off and pipe
retracted
0 0
---
Basic setting
Pipe extended
230 V
0
12 µF + 8 µF
+ 2.7 K
Ω
Setting 1
0
230 V
8 µF + 2.7 K
Ω
Setting 2
230 V
0
12 µF
Setting 3
0
230 V
Without circuit
4.3
Current and power table with GB 031-107
The measured values may differ due to fluctuating mains.
The following values were measured at 228 V
Current I in A
Power P in W
Off 0 0
Basic setting
0.55
49
Setting 1
0.78
105
Setting 2
0.90
165
Setting 3
0.86
195
4.4 Lifting
motor
The lifting motor is a direct-voltage motor 24 V DC.