Installation instructions
en
21
7.
Provide an intermediate floor between the appliance
and the top drawer.
8.
Observe the clearance between the intermediate
floor and the worktop.
Creating ventilation openings
Requirement:
The appliance requires sufficient ventila-
tion from below to function correctly.
1.
Make a unit cut-out in the upper area on the rear of
the unit.
2.
Observe the minimum clearances.
3.
If there is no minimum clearance at the rear of the
unit, make a unit cut-out in the bottom of the unit.
4.
Ensure that the base of the unit is sufficiently ventil-
ated.
5.
When installing in a cooking island, ensure that the
appliance is well ventilated.
17.10 Installing the appliance
WARNING ‒ Risk of electric shock!
If the insulation of the power cord is damaged, this is
dangerous.
▶
Never let the power cord come into contact with hot
appliance parts or heat sources.
▶
Never let the power cord come into contact with
sharp points or edges.
▶
Never kink, crush or modify the power cord.
1.
Keeping the appliance level, insert it into the unit
cut-out.
2.
If the oven is a built-under type, route the mains
connection cable along the rear corners of the oven
to the mains socket.
17.11 Establishing the power supply
1.
Observe the connection data on the rating plate.