6.2 Installation

WARNING - TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:

a.) Installation work and electrical wiring must be

done by qualified person(s) in accordance with
all applicable codes and standards, including 
fire-rated construction.

b.) Sufficient air is needed for proper combustion

end exhausting of gases through the flue 
(chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment 
manufacturer’s guideline and safety standards
such as those published by the National Fire 
Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air 
Conditioning (ASHRAE), and the local code 
authorities.

c.) When cutting or drilling into wall or ceiling, do

not damage electrical wiring and other hidden
utilities.

d.) Ducted fans must always be vented to the 

outdoors.

e.) If this unit is to be installed over a tub or shower,

it must be marked as appropriate for the appli-
cation and be connected to a GFCI (Ground
Fault Circuit Interrupter) - protected branch 
circuit.

f.) NEVER place a switch where it can be reached

from a tub or shower.

WARNING:

To reduce the risk of fire, use only metal ductwork.

The applicable regulations of the energy supply
companies and the 

regional construction regula-

tions

must be observed when installing the hood.

The minimum distance from the worktop to the 
bottom edge of the wall hood is for electrical appli-
ances 24 ´ ´ / 600 mm and for gas appliances 30 ´ ´ / 
762 mm.

The extractor hood was conceived for the 

exhaust

air mode

. The exhaust air can be routed into a se-

parate exhaust air shaft or directly into the open
through the outside wall.

It is not allowed to pass the exhaust air into a flue 
or exhaust air chimney that is in operation or into a
shaft that is linked to the heating basement. Consult
the chimney sweep responsible for your district
whenever you wish to pass the exhaust air into a
chimney that is not in operation.

During the course of planning

, a chimney sweep

must be consulted if a room air-dependent hearth 
is operated in the same room as the one in which a
hood is operated in the exhaust air mode. Adequate
incoming air must be ensured. The applicable con-
struction and safety regulations must be observed.

Adequate incoming air must be ensured if a wood,
coal, gas or oil heater or an open hearth is operated
in the same room as the one in which the hood is 
installed.

Safe operation is possible whenever the partial 
vacuum in the place where the firing equipment 
is installed does not exceed 4 Pa (0.04 mbar). 
This can be achieved whenever the air needed for
combustion is able to enter through openings that
cannot be sealed, for example in doors, windows,
incoming/exhaust air wall boxes or by other techni-
cal means.

14

Содержание AH 590-720

Страница 1: ...Operating and assembly instructions AH 590 720 Freely Suspended Insular Hood...

Страница 2: ...1 AH 590 720 6 Assembly instructions Page 13 19 6 1 Technical data Page 13 6 2 Installation Page 14 19...

Страница 3: ...or perfect functioning of the appliance at its installation location He must explain the operating principle of the appliance to the user with refe rence to the operating instructions He must explain...

Страница 4: ...ons must be observed when installing the hood The minimum distance from the worktop to the bottom edge of the wall hood is for electrical appli ances 24 600 mm and for gas appliances 30 762 mm The ext...

Страница 5: ...t air shaft our condensate separator RV 060 150 must be installed in the exhaust air line The condensate separator must still be accessible after installation The duct units listed below are available...

Страница 6: ...hob During operation the heat load of all hotplates and oven must not exceed 13 5 kW Should the nominal heat loads of all hotplates com bined exceed 13 5 kW e g combination with WOK burner during ope...

Страница 7: ...ust be on the same side as the control panel Fig 20 Ventilation ducts LK 590 020 030 021 031 only the enclosed extension module should be mounted on top of the support frame Follow the above instructi...

Страница 8: ...Stainless steel ventilation ducts only LK 590 010 020 030 pull the protective film off the metal surface 8 Place both ventilation ducts over the support frame Take care not to scratch the sensitive d...

Страница 9: ...on the support frame Fig 24 Note avoid scratches when pulling the ele ments apart by placing the assembly template for example over the top edge of the bottom duct to protect it 15 Replace the glass p...

Страница 10: ...1 McFADDEN AVENUE HUNTINGTON BEACH CA 92649 USA Y 800 828 9165 FAX 714 901 0979 www gaggenau com us GAGGENAU HAUSGER TE GMBH P O BOX 10 02 50 D 80076 M NCHEN GERMANY Y 0 89 45 90 01 FAX 0 89 45 90 23...

Отзывы: