20
Flat ducts
The inner cross-section must correspond to the
diameter of the round pipes.
dia. 6” (150 mm) approx. 27
^
sq in (177 cm
2
)
dia. 4
_
” (120 mm) approx. 26
_
sq in (113 cm
2
)
▯
Flat ducts should have no sharp deflections.
▯
Use sealing strip for deviating pipe diameters.
Preparing the units
▯
The fitted unit must be level and have sufficient
load-bearing capacity.
▯
The max. weight of the extractor hood is 40 lbs
(18
kg).
Appliance dimensions and safety clearances
▯
Observe the appliance's dimensions.
▯
Comply with the safety clearances.
If the installation instructions for the gas cooking
appliances specify a different distance, the largest
distance must always be provided for.
Fitted units must be heat-resistant up to 194° F
(90 °C). The stability of the fitted unit must also be
guaranteed after the cut-out work.
To install the extractor hood in a top cupboard, the
extractor hood must be provided with the following
dimensions:
1
Make cut-out for the exhaust air pipe. To do this,
make an opening in the top or back panel of the
fitted unit with an additional recess for the
power cord.
Width
24" (600
mm)
Depth
min. 12
5
/
8
" (320
mm)
Depth
min. 13
¾" (350
mm) with lowering frame
Elevation
min. 16
9
/
16
" (420
mm)
Elevation
min. 24" (600
mm) with CleanAir air
recirculation module
èç¼ʓʘ
PP