ADDITIONAl EEG7000 CAPABIlITIES

16

light force Governing

 provides finer adjustment resolution for smaller actuators. It is designed to work with low current small actuators, 

like T1 ATB, ALR/ALN, 100/103/104 series and normally closed Cummins EFC actuators. Select Light Force Governing from the Engine 

Tuning 

 Tuning menu when using small actuators to improve adjustments as they respond very quickly to input changes over a smaller 

range of operating current, using a fraction of the PID and current output of a normal actuator.

lead circuit 

(default is ON) enables the speed controller to be more responsive and typically increases the range of gain adjustment. 

This function allows for more active control to increase the performance in typically slow engines. 

idle

 is set with Speed 1 of the speed control settings on the Engine Tuning menu.  

Smoke reduction

 is an adjustment made using the Start Fuel parameter in the Engine Tuning menu. This sets the actuator % applied 

during crank in order to start easily but not too high to reduce black smoke.

auxiliary enable

 enables connections to synchronizing and load sharing equipment.  This allows the adjustment of the speed requests 

through the auxiliary input voltage, accepting a 1 - 9 V DC signal, biased at 5 V, and selectable response polarity.  In response the 

EEG7000 will increase or decrease voltage but does not change engine speed. 

can

 

j1939

 bus device communication is supported to receive and display J1939 messages.

 imPortinG, exPortinG, anD reStorinG SettinGS

The EEG7000 offers a number of GAC specific capabilities as well as helpful tools.  

The GAConfig Tool allows settings in the tool to be stored, shared, 

and imported back into the tool for use on multiple EEG7000 con-

trollers.  Export settings at any time while using the GAConfig Tool. 

To export files

:

1. 

EEG7000 must be powered on and connected to the GAConfig Tool. 

2. 

At the Tool bar click the Export button. The Save as dialog allows you to select the location you want to save the file. 

To import files

:

1. 

EEG7000 must be turned on and connected to the GAConfig Tool. 

2. 

At the Tool bar click the Import button. The Save as dialog allows you to select the location you want to save the file. 

Best practice is to export engine settings information once the engine performs as desired.  Name the file using dates and intended use 

as part of the file name.  These files are helpful when shared with the GAC support team to aid further enhancing your settings. 

to restore the original Gac factory settings:

1. 

Shut the engine off. Factory restore can be done when the engine is off but the GAConfig Tool is running. 

2. 

Access the Quick Configuration 

 Advanced Configuration 

 

System Commands menu.  

3.  Click Factory Restore to set the EEG7000 to its factory settings. GAC factory settings are not the same settings used on an OEM 

version of the EEG7000. 

4.  To reset just the software settings, click System Reset. 

Parameter settings can be created before connecting to the engine and uploaded once the connection is made.  The EEG7000 must be 

connected to power and the PC.  
1. 

Click the Connect button on the Main menu. The Import Configuration menu displays asking if you want to import the settings you 

have recently created. 

2.  Click Import to update the EEG7000. The progress bar displays. If the controller is not ready or not connected they system displays 

an error message. 

 offline Set UP moDe

Содержание EEG7000

Страница 1: ...off road mobile equipment GAConfig Tool adds the ability to monitor and set parameters from your PC With CAN J1939 capabilities allow it to accept TSC1 messages over USB as a mini engine control modul...

Страница 2: ...cause personal injury or equipment damage Do not rely exclusively on the governor system electric actuator to prevent overspeed A secondary shutoff device such as a fuel solenoid must be used LED DEFI...

Страница 3: ...C or 4 20 mA selectable polarity 10 Battery Ground 16 Battery ground 11 Battery Power 16 A 10 A fuse must be installed in the positive battery lead to protect against any overload or short circuit or...

Страница 4: ...cable shield must only be connected to the case The shield should be insulated to ensure that no other part of it comes into contact with engine ground otherwise stray signals may be introduced into t...

Страница 5: ...lue and click Calibrate Minimum button To calibrate the maximum percent set the potentiometer to the highest end value and click Calibrate Maximum button The difference between the analog minimum spee...

Страница 6: ...ntiometer CW all the way and click Calibrate Maximum d Note the Input Actual result Variable Speed can be used as another fixed speed setting if both Speed Minimum and Speed Maximum parameters are set...

Страница 7: ...e please cal your GAC representative The default installation is in the Program Files x86 Governors America Corporation file area 3 The GAConfig Setup screen displays Click Install The Installing GACo...

Страница 8: ...RED warning boxes error information yellow cautions and other pop up information Setting some parameter values impact other parameter values often displaying a caution The GAConfig Tool windows autom...

Страница 9: ...NG Engine Tuning is the basic menu used to store your engine startup and tuning information Flywheel teeth overspeed fuel limit Start fuel rate Fuel ramp rate starter cutoff acceleration and decelerat...

Страница 10: ...uning improves performance Before you start your engine Install the GAConfig Tool on a PC and connect the PC to the EEG7000 with the USB cable Provide power to the EEG7000 from the battery Install an...

Страница 11: ...until instability develops Gradually decrease Stability value until stability returns Decrease the value by one to ensure it is stable If there is no instability leave set at 50 c Set the DEADTIME to...

Страница 12: ...speed while in variable speed Speed Maximum 150 6000 rpm 1500 Maximum speed setting Variable Speed End Gain 1 100 50 Gain to use when at the maximum speed while in variable speed Input Minimum Calibra...

Страница 13: ...y adding settings or use the automatic calibration buttons a To set calibration automatically Turn potentiometer fully CCW and click Calibrate Minimum Turn potentiometer fully CW and click Calibrate M...

Страница 14: ...le speed as needed The No Load Current value must be set to less than Full Load Current and the difference between the two must be at least 0 5 A If an invalid combination is entered a warning message...

Страница 15: ...econds 3 Click Start The data displays similar to shown below Note the time and rpm display when you move your cursor over the green timeline 4 To save the data click Save The file is saved as a print...

Страница 16: ...1500 1500 Set engine speeds Variable Speed Variable Speed Input Mode 4 20 mA or 0 5 V DC 0 5 V DC Sets variable speed input signal to 0 5 V DC or 4 20 mA Speed Minimum Speed Maximum 150 6000 150 6000...

Страница 17: ...orporate while in variable speed mode SAE J1939 Configuration J1939 Address 0 253 0 Sets the CAN address for J1939 communication Engine Requested Torque Speed 0 6000 rpm 1500 The value the controller...

Страница 18: ...39 compatible After initial configuration the CAN data is available on the J1939 Diagnostics Messages view on the GAConfig Tool or using a compatible controller Sample PGN transmit and receive codes a...

Страница 19: ...d diagnostics CONTINUED 15 PGN NAME VALID SPN s NOTES 0 Torque Speed Control 1 TSC1 SPN695 Engine Override Control Mode SPN898 Engine Requested Speed Speed Limit SPN3349 TSC1 Transmission Rate SPN4206...

Страница 20: ...0 offers a number of GAC specific capabilities as well as helpful tools The GAConfig Tool allows settings in the tool to be stored shared and imported back into the tool for use on multiple EEG7000 co...

Страница 21: ...tic Engine Behavior Increasing Stability reduces instability but does not totally correct it If this is the case there is most likely a problem with the engine itself Check for engine mis firings erra...

Страница 22: ...sure the voltage at the battery while cranking If the voltage is less than 7 V DC for a 12 V DC system or 14 V DC for a 24 V DC sys tem check or replace battery Momentarily connect Pins 1 and 11 The a...