GAC EEG6500 Скачать руководство пользователя страница 3

3

© 2018 Copyright All Rights Reserved

EEG6500 Enhanced Electronic Governor

   

05.09.18

    

 

PIB 5010

 

F

6

7

FEATURES

PRE-START SETUP & QUIKSET PARAMETERS

Special Menu 

Parameter

Quikset Menu 

Parameters

VSPD

MODE

SPEED

V. SPEED

OFF

Trim

(Default)

Application Rated Speed

(e.g., 1500 RPM)

Speed Trim 

(10 = ±10 Hz)

ON

Variable 

Speed

Minimum speed when 

potentiometer is at lowest 

resistance (e.g.,1000 

RPM)

Maximum Speed when po-

tentiometer is at the highest 

resistance

(e.g., 2000 RPM)

TRIM or VARIABLE SPEED OPERATION

Trim Function

 

- Performs finer adjustments (e.g. generator frequency) The 

resistive input speed function is active when the VSPD (Variable Speed) 

parameter is “OFF” (default value is OFF).  5K Ohm potentiometer typical.

Variable Speed Function

 

- Operates over a larger RPM range.  Variable 

speed 0 - 2.5 volt input to terminal ‘J’ is active when VSPD (Variable Speed) 

parameter is “ON”.

IDLE SPEED

Set the parameters below before starting the engine:

#TEETH

Input the Number of Teeth on the Flywheel. This can not be changed while 

engine is running.

CRANK

Input the Crank Termination (RPM)

SPEED

Input the Fixed Speed of the Engine (RPM)

ADJUSTABLE QUIKSET PARAMETERS 

OVER SPEED *

#TEETH

CRANK *

Range: 400 - 6000 RPM

Default: 2000 RPM

Range: 60 - 250

Default: 120

Range: 100 - 1000 RPM

Default: 400 RPM

RPM to automatically 

shutoff the actuator

Number of teeth on 

flywheel

RPM which EEG switches 

from starting fuel limit to 

fuel limit

SPEED RAMP

V.SPEED *

LOCKED

Range: 25 - 2000

Default: 300

Range: 0-6000 RPM (vspd)

0-120 Hz (trim)

Default: 1800 RPM (vspd)

    : 0 Hz (trim)

Range: OFF, ON

Default: OFF

Rate at which speed 

changes from idle to set 

speed and back, or rate 

change in variable speed 

mode.

Maximum speed change 

allowed from trim input

Enables Manual/Auto 

locking of display.  Press 
and hold UP and DOWN 

arrows simultaneously for 
3 seconds to UNLOCK or  

LOCK the display.

START FUEL

DROOP%

FUEL RAMP

Range: 0 - 100%

Default: 100%

Range: 0 - 25.0% 

Default: 5.0%

Range: 1 - 100% / Sec.

Default: 10%

Initial actuator position at 

the start of cranking

Droop to apply under 

maximum load (based on 

current of actuator)

Actuator position increase 

in percent per second from 

cranking to low idle speed, 

starting from the ‘Start 

Fuel’ position

SPEED  *

IDLE *

FUEL LIM

Range: 0-6000 RPM(fixed)

   0-6000 RPM(droop)

Default: 1500 RPM(fixed)

                   50 RPM(droop)

Range: 150 - 1500 RPM

Default: 900 RPM

Range: 0 - 100%

Default: 100%

Operating speed of engine

Speed of engine when 

IDLE input is closed

Maximum actuator 

percentage allowed

GAIN

STABILITY

DEADTIME

Range: 1 - 100, 

100 = Max Gain

Default: 50 (rated)

        : 10 (idle)

Range: 1 - 100, 

100 = fastest response

Default: 50

Range: LOW, HI

Default: HI

Proportional (P) set point 

of the PID control at oper-

ating SPEED and IDLE

Integral (I) set point of the 

PID control

Derivative (D) set point of 

the PID control

The optional external switch must be connected between 
terminals “H” and “L”.  A pressure switch may also be used 

as a method of enabling.  When enabled, IDLE has an independent Gain 
adjustment.

IMPORTANT

IMPORTANT

Increasing voltage, resistance or current increases speed.

RESISTIVE, VOLTAGE OR CURRENT INPUT TO TERMINAL ‘J’

COM

A

D

C

B

E

H

G

F

L

K

J

M

H

J

5KΩ

CCW

Terminal J Utilizes A 
CCW Potentiometer

VSPD

ACCESSORY INPUT

The Auxilary (Aux) input, terminal ‘M’, accepts signals from auto synchroniz-

ers, load sharing units, and other GAC accessories.

* Maximum 12KHz

End User Interface

Secondary 
Parameter

Actuator Duty Cycle

100%= 11 Bars
90-99% = 10 bars
...
10-19% = 2 bars
1-95% = 1 bar
0% = 0 bars

Primary Parameter Value (Blinks if restart required) 

Primary Parameter Units

Pressing either UP or DOWN arrow moves the primary and 
secondary parameters to the next parameter set. The list is 
always traversed in one direction.

Primary Parameter (Units)    

 

Engine Speed (RPM)        
Duty Cycle (%)
Actuator Current (A)

Engine Speed (Hz)
V-Speed (%)

Secondary Parameter 

Actuator Duty Cycle
Engine Speed relative to set point

Conversion Formulas:

    Hertz

MAG PICKUP 

=  (RPM x # Teeth)

                                      60sec
    RPM =  (Hertz

MAG PICKUP 

x 60sec)

                             # Teeth

Engine Speed

Middle bar = set point
Top bar = Set point + 10 RPM
Bottom bar = set point - 10 RPM

PRE-START SET-UP & QUICKSET PARAMETERS

4-20mA input requires an external 200 Ohm resistor across H & J

Содержание EEG6500

Страница 1: ...t Display mm in Dimensions COM VSPD EEGEnhanced Electronic Governor 6500 www governors america com CAUTION ENGINE SPEED CONTROL COMPONENT SEE PRODUCT PUBLICATION WHEN INSTALLING OR SERVICING N P CAN M...

Страница 2: ...3 Parameter Adjust Up Parameter Adjust Down Increment a Parameter Value HOLD and TAP or Rapidly Increment a Value HOLD and HOLD or Locking Unlocking the Display Press and hold both the UP and DOWN ar...

Страница 3: ...or position at the start of cranking Droop to apply under maximum load based on current of actuator Actuator position increase in percent per second from cranking to low idle speed starting from the S...

Страница 4: ...l blink QUIKSET MENU PARAMETER ADJUSTMENT PROCEDURE A GAIN 1 2 3 4 Increase this parameter until instability develops Then gradually decrease this parameter until stability returns Finally decrease th...

Страница 5: ...EAD CIRCUIT Turning the Lead Circuit LEAD ON default is ON enables the governor to be more responsive and typically increases the range of GAIN adjustement Turn Lead Circuit ON when there is slow or m...

Страница 6: ...k and failures will cause a system shut down 11 FAULT CODES ADVANCED MENU PARAMETERS CONFIGURABLE CODE CAUSE EFFECT CUSTOMER ACTION 1 Actuator over current continuous Actuator turned off for 30 sec Ch...

Страница 7: ...america com www governors america com SYMPTOM NORMAL READING PROBABLE CAUSE OF ABNORMAL READING Engine Over Speeds 1 Do Not Crank Apply DC power to the governor system 1 If the actuator is at minimum...

Страница 8: ...R SETTINGS Parameter Factory Settings Customer Settings Gain 50 Rated 10 Idle Stability 50 Deadtime HI Speed 1500RPM Idle 900 RPM Fuel Limit 100 Start Fuel 100 Droop 5 0 Fuel Ramp 10 Speed Ramp 300 RP...