manualshive.com logo in svg
background image

Air Conditioner

Owner's Manual

                      

 

MODELO:

 

        

                              

IGB09MB-K3DNB7G

                              

IGB12MB-K3DNB7G

IGB18MC-K3DNB7G

                                

  

Split Air Conditioner

Thank you for choosing our product.

If you have lost the Owner’s Manual, please contact the local agent or visit 

www.elnur.es or sent email to [email protected] for electronic version.

For proper operation, please read and keep this manual carefully. 

Содержание IGB12MB-K3DNB7G

Страница 1: ...MC K3DNB7G Split Air Conditioner Thank you for choosing our product If you have lost the Owner s Manual please contact the local agent or visit www elnur es or sent email to elnur elnur es for electro...

Страница 2: ......

Страница 3: ...est and operation Test operation 33 Attachment 34 Pipe expanding method 36 This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent poss...

Страница 4: ...pliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowl...

Страница 5: ...amage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not...

Страница 6: ...les before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Pr...

Страница 7: ...nnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only Precautions WARNING wire which can t be used for other purposes The grounding resistance s...

Страница 8: ...e installed in the line For the air conditioner without plug an circuit break Select a location which is out of reach for children and For the air conditioner with plug the plug should be Working temp...

Страница 9: ...air outlet Connection wire Parts name Indoor Unit air inlet panel aux button horizontal louver air outlet heating indicator temp indicator cooling indicator power indicator receiver window drying indi...

Страница 10: ...GHT button 7 CLOCK button 6 TIMER ON button Up down swing Child Lock set time TIMER ON TIMER OFF turbo mode set temperature X fan send signal set fan speed light Temp display type Set temp Outdoor amb...

Страница 11: ...indicator on indoor unit is ON You can press or button to adjust set temperature Press FAN button to adjust fan speed Press button to adjust swing angle Cooling only unit can t receive the signal for...

Страница 12: ...n motor will adjust the fan speed high medium or low speed according to ambient temperature Fan speed under dry mode is low speed Press this button can select up down swing Swing angle can be selected...

Страница 13: ...increase or decrease half an hour When holding or button 2s later the time will change quickly until to Cancel TIMER OFF Press TIMER button again under TIMER OFF status At OFF status press this button...

Страница 14: ...ress X FAN button can turn off X FAN function Indoor fan stops operation immediately Press this button can see indoor set temperature indoor ambient temperature or outdoor ambient temperature on indoo...

Страница 15: ...ill be displayed on remote controller Press this button again to cancel sleep function icon on remote controller will be displayed Press this button can turn off the light for indoor unit s display ic...

Страница 16: ...obstacles between them or wireless telephone remote controller should be close to indoor unit during operation Replace new batteries of the same model when replacement is required When you don t use...

Страница 17: ...the air conditioner The operation in details are as below WARNING NOTICE Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash t...

Страница 18: ...panel Pull out the panel to a certain Use dust catcher or water to the water below 45 to clean it and then put it in a shady and cool place to dry panel cover tightly operation environment clean freq...

Страница 19: ...e pipe is damaged 1 Disconnect power supply 3 Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer Notice for recovery 1 Many packing materials are recyc...

Страница 20: ...Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re ceivin...

Страница 21: ...r temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temp...

Страница 22: ...gain Outdoor unit has vapor Heating mode is turned on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water flowing noise Air conditioner is turned on or turne...

Страница 23: ...ting or oil return mode It is normal The indicating lamp in heat mode will wink 0 5s and light 10s E5 overcurrent protection Power indicator blinks and E5 is displayed C5 Connector jumper malfunction...

Страница 24: ...t 50cm At least 30cm At least 300cm At least 200cm Space to the obstruction Space to the obstruction Space to the obstruction Space to the ceiling Space to the obstruction Space to the obstruction At...

Страница 25: ...ed power cord Basic requirement Outdoor unit Indoor unit Installing the unit in the following pla ces maycause malfunction If it is un avoidable please consult the local dealer 1 The place with strong...

Страница 26: ...led in accordance with national wiring regulations 10 Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only grounding with specialized grounding...

Страница 27: ...uld be a little lower than the wall mounted frame shown as below Step three open piping hole 2 Open a piping hole with the diameter of 55 on the selected outlet pipe position In order to drain smoothl...

Страница 28: ...out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left l...

Страница 29: ...60 65 70 75 15 20 insulating pipe 1 Connect the drain hose to the outlet pipe of indoor unit 2 Bind the joint with tape outlet pipe drain hose drain hose tape outlet pipe drain hose insulating pipe N...

Страница 30: ...it and outdoor unit should be connected by a professional for a new one Avoid extending the wire by yourself installation For the air conditioner without plug an air switch must be installed in the li...

Страница 31: ...ately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the indo...

Страница 32: ...the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capacity of 10000...

Страница 33: ...ipe liquid valve gas valve union nut pipe joint Hex nut diameter Tightening torque N m 6 9 52 12 16 19 30 40 45 55 60 65 70 75 15 20 1 Remove the wire clip connect the power connection wire and signal...

Страница 34: ...ightly dow nwards The drain hose can t be curved raised and fluctuant etc The water outlet can t be placed in water in order to drain smoothly Installation of outdoor unit U shaped curve wall drain ho...

Страница 35: ...decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw caps of valves and refrigerant charg...

Страница 36: ...t grounded securely It may cause electric leakage Does the power cord follow the speci fication It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet It m...

Страница 37: ...efrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolonged length of liquid pipe additional ref...

Страница 38: ...Diameter of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 12 16 19 22 2 9 52 or 12 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350 12...

Страница 39: ...uitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the port...

Страница 40: ...8110 Algete Madrid Tfno de Atenci n al Cliente 34 91 628 1440 www elnur es www elnur global com www elnur co uk As a part of the policy of continuous product improvement Elnur s a reserves the right t...

Отзывы: