Operation instructions
1. Open housing with include security key previously retained.
2. Open cover on bettery compartment, remove battery box and unplug cable. Install 6 new alka-
line type AA 1,5 V baterries with correct polarity (note +/- indication) to obtain 4,5 V DC +/- 10%
at the plug.
3. Reinstall bettery box and close compartment cover.
4. Obtain a disposable soap cartridge (800 ml) or remove.
Clean out and refill the included reusable soap reservoir with the correct viscosity liquid soap.
Install either in the dispenser ensure that:
• Soap container cover is closed.
• Ait vent hole is open.
• Nozzle is not clogged.
• Soap container is clean (no spill-over).
• Not leaking.
Make sure the nozzle flange is below the housing cradle rib to stretch the valve tube.
5. Observe that the LED is light blue and then flashes 3 times indicating condition and ‘’stand-by’’
condition and battery charge level (press and push up the cover safety interlock switch (blue stem)
on bottom to click and hold it).
6. Close the housing cover and lock it with the included security key previously retained.
7. Trigger the sensor with hands or towel to check proper soap dispensing cycle.
Sensing range adjustment
Sensing range is pre-set and adjusted by the factory to be 80-100 mm. If the range must be
adjusted proceed as follows:
1. Find a service access hole at the bottom of the product.
2. Close the housing cover and lock it with the included security key previously retained.
3. Use a flat blade electronics screw driver with a tip maximum to rotate the potentiometer knob
inside the control module through the access hole in the bottom housing by ¼ turn at a time
between testing for results as follows:
• Clockwise to increase distance.
• Counter clockwise to decrease sensing distance.
Battery low indication
With housing cover open and soap reservoir removed (see instructions) perform the following
diagnostic test:
1. Press and push up the cover safety interlock switch (blue stem) on bottom to click and hold it.
2. Observe that the LED is light blue and then flashes 3 times indicating proper operation ‘’stand-
-by’’ condition and battery charge level.
3. If LED continues to flash blue the indication is positive to replace the batteries.
The English version of the manual is an exact translation of the original manufacturer‘s instructions.
Images used in this manual are for illustrational purposes only and may differ from the actual product.