background image

 
 
 

BDA OVERVIEW: 

 

The BDA assembly extends the coverage area of radio communications in buildings 
and RF shielded environments. The BDA has dual RF paths to extend coverage in 
two distinct frequency bands.    
 
The unit features low noise figure and wide dynamic range. It is based on a duplexed 
path configuration with sharp out of band attenuation allowing improved isolation 
between the receiving and transmitting paths.    

 

BDA DESCRIPTION: 

 

The BDA Downlink path receives RF signals from the base station and amplifies and 
transmits them to the subscriber. The BDA Uplink path receives RF signals from the 
subscriber and amplifies and transmits them to the base station. The Uplink and 
Downlink occupy three distinct frequency bands. The frequency bands are as follows: 
794-824 MHz for the Uplink and 764-776 MHz & 851-869 MHz for the Downlink. Two 
triplexers isolate the paths and route each signal to the proper amplifying channel. 
 
An Automatic Level Control (ALC) allows for output power limiting. A variable step 
attenuator gives 0 – 30 dB of attenuation in 2 dB steps. The use of these controls is 
covered in the “OPERATION” section, later in this document.  
 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Page 3 

Содержание BDA-PS8-2

Страница 1: ...INSTALLATION AND OPERATING MANUAL BDA PS7 PS8 2 2W 80 A DUAL BAND BI DIRECTIONAL AMPLIFIER...

Страница 2: ...ONS 4 MECHANICAL SPECIFICATIONS 5 ENVIRONMENTAL CONDITIONS 5 BDA CONNECTIONS 5 MECHANICAL OUTLINE DRAWING Figure 1 1a 6 BDA INSTALLATION 7 BDA OPERATION 8 UPLINK MECHANICAL OUTLINE ADJUSTMENT Figure 2...

Страница 3: ...from the base station and amplifies and transmits them to the subscriber The BDA Uplink path receives RF signals from the subscriber and amplifies and transmits them to the base station The Uplink and...

Страница 4: ...26 dBm Isolation between Up Down Link 100 dB min Input Output Impedance 50 Ohms VSWR Input Output 1 5 1 max Pass band Gain min attenuation 80 dB minimum Power Supply 110VAC 1 42Amp 240VAC 0 71 Amp 50...

Страница 5: ...connector provides failure alarm output contacts see diagram next page as well as an optional 12 VDC 250mA auxiliary output The RF connections are made via two type N female connectors The RF connecto...

Страница 6: ...ine Figure 1a Relay Shown in Non Alarm Condition The alarm monitors current of both uplink and downlink amplifiers An alarm condition will occur if either uplink or downlink amplifiers are over or und...

Страница 7: ...to the BDA connector labeled BASE and the cable from the service antennas to the BDA connector labeled MOBILE 4 Open the adjustment access panels on the sides of the BDA and verify that both of the a...

Страница 8: ...to the factory preset level of 26 dBm ALC function is located on each amplifier and accessible via the access door on the BDA enclosure A red indicator lamp located on each amplifier illuminates when...

Страница 9: ...Figure 2 Uplink Adjustment Access Panel and Label Page 9 OFF ON ALC 0 30 UPLI NK...

Страница 10: ...Figure 3 Downlink Adjustment Access Panel and Label Page 10 0 30 DOW NLINK OFF ON ALC...

Страница 11: ...quires no periodic maintenance There are no user serviceable components inside the BDA This section covers possible problems that may be related to the installation or operating environment a Gain Red...

Отзывы: