background image

 
 

16 | 

P a g e

 

 

APPENDIX 1  

 

26-Pin Connector

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Conditions for Donor Alarm (26-pin)

 

 

 

This functionality applies only for a Donor antenna with a 
DC short. Alarm monitors the connection of the BDA to 
the donor antenna.  An alarm

 

condition will occur if there  

is a disconnect at the donor antenna. Uplink and 
Downlink amplifiers will shut down. Donor Alarm, Current 
DL, and Current UL will indicate. 

 

 

Test for DC short between male pin and 

outer shell of antenna connectors 

 

 

 

 

Figure 7a

 

If the donor antenna does not short please connect        
G-Way’s special Donor Short Simulator.  

 

Please note, if you intend to use other components (i.e. 
Lightning Protector) between the base port and donor antenna 
make sure they have an open short. 

 

N Type Female/Female 
Donor Short Simulator  

   N Type Male/Female 

Donor Short Simulator

 

 

Figure 7b

 

Conditions for DC Backup Alarm  

The alarm monitors the AC power. If the AC power 
fails and DC is connected, the DC Alarm LED will 
indicate DC power.

 

 

 
Conditions for Mobile Alarm

 

*OPTIONAL

 

The alarm monitors mobile antenna conditions to the 
VSWR. In poor conditions, Mobile Alarm and Current UL 
will indicate.

     

 

 

 

Mobile Antenna Failure contacts 

are not standard in the O26 pin-

out and must be requested at 

time of order to be included. 

Содержание BDA-PS7W-37/37-90-C

Страница 1: ...Installation and Operating Manual BDA PS7W 37 37 90 C Public Safety 700 MHz Band Bi Directional Amplifier ...

Страница 2: ...INDUSTRY CANADA 4 ELECTRICAL SPECIFICATIONS 6 MECHANICAL SPECIFICATIONS 6 ENVIRONMENTAL CONDITIONS 6 MECHANICAL OUTLINE 8 CONNECTIONS 9 AVAILABLE OPTIONAL FEATURES 10 ALARM CONDITIONS 11 VARIABLE GAIN ADJUSTMENT AND LED INDICATORS 12 INSTALLATION 13 OPERATION 14 DIAGNOSTICS GUIDE 15 ANTENNA SEPERATION 15 APPENDIX 1 16 APPENDIX 1 17 APPENDIX 2 18 ...

Страница 3: ...ment shouldn t be used if this protection is impaired The supplied power cord must be used along with an uninterrupted external power source HAZARDOUS LINE AND RF VOLTAGES This symbol is marked on the equipment where dangerous voltages are present Use extreme caution Both RF input and output connectors should be terminated prior to the application of the external AC source Otherwise contact with t...

Страница 4: ...evice RF EXPOSURE WARNING FCC The ERP limit as defined by the FCC is 37 dBm In order to comply with the FCC RF exposure requirements the antenna installation must comply with the following The Omni directional antenna or leaky cable must be installed so as to provide a minimum separation distance of at least 30 8 cm 12 2 inches between the antenna connected to the RF booster and the human user s b...

Страница 5: ...ttenuator gives 0 30 dB of attenuation in 2 dB steps The use of these controls is covered in the OPERATION section later in this document BLOCK DIAGRAM DESCRIPTION Figure 1 Block Diagram 1 Diplexer Separates Combines UL and DL pass bands provides needed isolation and selectivity to support system gain 2 Downlink Low noise amplifier and driver Exhibits low noise figure and high linearity 3 Downlink...

Страница 6: ...CIFICATIONS May vary per unit see spec for more accurate information Size 14 x 6 7 x18 1 RF Connectors N Type Female Weight 37 8 lb ENVIRONMENTAL CONDITIONS The unit is designed for indoor applications Operating temperature 30 C to 55 C Storage temperature 40 C to 85 C Composite Output Power 25 dBm 27 dBm 33 dBm 37 dBm Gain Flatness dB 1 5 2 0 1 5 1 5 Noise Figure dB 5 0 Max 4 5 Typ 5 0 Max 4 5 Ty...

Страница 7: ...Output Composite Power Typical DC Current Draw 24VDC A Battery Back Up Time Hours Recommend Battery Rated Capacity 20 Hour Rate Amp Hours 37 dBm 3 55 4 17 75 8 35 5 12 53 25 24 106 5 33 dBm 2 47 4 12 35 8 24 7 12 37 05 24 74 1 31 dBm 2 35 4 11 75 8 23 5 12 35 25 24 70 5 27 dBm 2 1 4 10 5 8 21 12 31 5 24 63 Note We do not guarantee specifications under Battery Back Up power ...

Страница 8: ...8 P a g e MECHANICAL OUTLINE Figure 3 Mechanical Outline ...

Страница 9: ...ctions must be made through cables with characteristic impedance of 50 ohms The BDA AC power is accepted through a standard 3 wire male plug IEC 320 with phase neutral and ground leads The AC power is wired to a high efficiency DC switching power supply which is CE and UL approved The power supply runs the amplifiers and the LED indicators The metal enclosure of the BDA is connected to ground Addi...

Страница 10: ...nto a building s alarm system Dry contact will provide alarms for ALC and amplifier failure Local Alarming via dry contact 26 Pin Connector 026 A 26 Pin dry contact will be provided to hard wire into a building s alarm system Dry contact will provide alarms for ALC amplifier failure donor antenna failure and DC backup failure See details in appendix 1 Oscillation Detector and Shutdown ODSC ODSCRM7...

Страница 11: ...n individual from accidentally pulling AC cord from unit as well as providing additional protection against direct water ALARM CONDITIONS The alarm monitors the current of both the uplink and downlink amplifiers An alarm condition will occur if either the uplink or downlink amplifiers are over or under its current tolerance Additionally each failure alarm indicator from the available features may ...

Страница 12: ...Illuminates when the UL amplifier fails External DC LED optional Illuminates when the BDA is operating from a DC source Oscillation detection LED optional Illuminates when oscillation is detected Donor antenna alarm LED optional Illuminates when Donor Antenna is disconnected Mobile antenna alarm LED optional Illuminates when the mobile port is disconnected DL Manual Gain Attenuator Is a switch use...

Страница 13: ...s than the BDA gain will give rise to oscillations which will saturate the amplifiers and possibly cause damage to the BDA 3 Connect the cable from the donor antenna to the BDA connector labeled BASE and the cable from the service antennas to the BDA connector labeled MOBILE 4 See main Panel of the BDA and verify that both of the Uplink and Downlink attenuation is set to 30 dB via dial Attenuator ...

Страница 14: ...s located in each power amplifier A red LED indicator located inside the BDA enclosure see figure 5 illuminates when output power meets or exceeds the ALC preset point To establish proper operating gain on the Uplink and Downlink paths begin with the Downlink Observe the red LED indicator labeled DL ALC Units are shipped from the factory with maximum attenuation 30 dB Decrease attenuation one step...

Страница 15: ...een those antennas is 15db above the system gain The amount of isolation that can be achieved between antennas depends on several factors such as the physical vertical and horizontal separation distance between the antennas polarization radiation pattern of the antennas the medium between the antennas antenna gain etc Antenna isolation can most accurately be determined through on site measurements...

Страница 16: ...nnect G Way s special Donor Short Simulator Please note if you intend to use other components i e Lightning Protector between the base port and donor antenna make sure they have an open short N Type Female Female Donor Short Simulator N Type Male Female Donor Short Simulator Figure 7b Conditions for DC Backup Alarm The alarm monitors the AC power If the AC power fails and DC is connected the DC Al...

Страница 17: ...17 P a g e APPENDIX 1 O26 Alarm Block Diagram ...

Страница 18: ...etween horizontally separated transmitter and receiver antennas dh m the horizontal distance from the centre of interferer antenna to that of the interfered with receiver antenna dv m the vertical distance from the interferer antenna to the interfered with receiver antenna measured from radiation center to radiation center f Hz the wavelength of the interfered with system frequency band GTx dBi ga...

Отзывы: