13
5
Gravity Acceleration Setting Mode
5.1
How to Enter Gravity Acceleration Setting Mode
: Press "
On/Off
" Key to turn on the power and press “
ZERO
” Key until the booting is
completed to show "CAL4" on the display and enter Gravity Acceleration Mode.
-
ZERO
Key: Add 1 to the flickering digit
-
TARE
Key: Move the flickering digit to the left
-
Key: Save the settings and enter Measurement Mode
* The gravity constant compensation function is not set at the factory. To use this function,
you must separately set the gravity constant value and calibrate it.
6
General Setting Mode
6.1
How to Enter General Setting Mode
: Press "ON/OFF" Key to turn on the power and press “ZERO” and “TARE” Keys until the
booting is completed to show "p-zero" on the display and enter General Setting Mode. Use
below Keys to change settings.
-
UNIT
Key: Change setting type and setting value.
-
TARE
Key: Select settings
Description of General Setting Mode
Type
Initial Value
Setting Value
Description
p-zero
3
It sets the range of initial zero point.
(e.g.) When the setting value is set 10, it means to be
within ±10% of capacity.
5
●
10
20
30
40
50
100
Type
Initial Value
Setting Value
Description
z-rang
●
2
It sets the range of zero key function.
(e.g.) When the setting value is set 2, it means to be
within ±2% of capacity.
3
4
10
20
Содержание GL-6000L Series
Страница 2: ...2 ...
Страница 5: ...5 ...
Страница 6: ...6 ...
Страница 8: ...8 2 2 Product Size ...
Страница 22: ...22 9 How to Download Program 9 1 Downloader Connection ...
Страница 23: ...23 9 2 How to Download STEP1 Initiate HOPE3000FOR8051 program STEP2 Click File Open and Download ...
Страница 24: ...24 STEP3 Choose hex file STEP4 Select HT85F2280 and click 0K ...
Страница 25: ...25 STEP5 Choose ICP e C0N12C and click OK STEP6 Click Smart Programming ...
Страница 29: ...29 11 How to Sealing ...
Страница 30: ...30 12 GL6000L Series MS EXPLODED ...
Страница 31: ...31 ...
Страница 33: ...33 MEMO ...
Страница 34: ...34 MEMO ...
Страница 35: ...35 MEMO ...