background image

How to use the 2G/3G Beam Alarm

Once you have positioned the beams, installed the simcard and programmed the
numbers the system is ready to use.

The GSM Wireless Beam Alarm has two modes, alarm mode and auto mode.

Alarm mode: 

you have to arm the alarm manually each time when required via a text

message command or via the keyfob provided.

Auto mode:

 the alarm is always armed. You should choose which mode is more suitable to

your application.

These modes are selected by sending the following text messages

#

Mode

=

1

Auto Mode

#

Mode

=

2

#

 

Alarm Mode (default)

The default setting is alarm mode, to get an alarm notification when the beam is triggered,
you will need to arm the alarm first via text message or key fob

Arm Via Text Message

To set the alarm to ON you will need to send the text message

#

ALARM

=

ON

This will activate the alarm

#

ALARM

=

OFF

#

 

This will deactivate the alarm

It is important to remember that once the alarm has been triggered you will need to reset
the alarm by sending the text command 

#

ALARM

=

ON

#

 to reactivate the alarm or activate it

using the key fob.

Arm Via Key Fob

The key fob works best when used with the siren provided as you will get the audible alert
whenever you arm or disarm the alarm.

Press button A on the key fob 

Arms the alarm and siren will beep twice

Press button B on the key fob 

Disarms the alarm and the siren will beep twice

Again it is important to remember that when the alarm has been triggered you will need to
reset the alarm using either the text command (above) or by using the fey fob.

In auto mode, the key fob and text message are disabled, the alarm is always
Active , after the alarm is triggered it will automatically reset  to active after 20 seconds

In the event of a power loss the unit will remember if it was armed when power is restored

How to use the Relay Output

The relay has been programmed to trigger the siren for 60 seconds in the event of an
alarm activation. Once the text message and call has been received you can stop the siren
sounding by pressing B on the key fob.

If you do not require the siren to sound in the event of an alarm activation but require it so
that you hear the key fob activation you can turn the siren off by Dipswitch 1.

Dipswitch 1 ON = Siren is turned ON

Dipswitch 1 OFF = Siren turned OFF

If you require the ability for the relay to be independently activated like older versions of
this alarm, please contact us on 01798 861346

Page 7

Содержание ECO-BEAM

Страница 1: ...Page 1 2G 3G GSM Wireless Beam Alarm www gsm activate co uk MODEL ECO BEAM ...

Страница 2: ...eratures GSM Module Specification GSM Frequency Quadband freq 850 900 1800 1900 3G Model 2100 Mhz Power Supply Voltage 9 24 volts DC 1 Amp Min Current used in standby mode 60mA Max IP65 Enclosure rating for outside installation 2 Amp Relay Output Micro 2G or 3G Simcard No land line required Dimensions L100 x W68 x H50mm Dimensions PCB Only L95 x W67mm Sim Active Function Operating Temperature 10 4...

Страница 3: ...n a suitable position you can text the unit to see how much signal strength the detector is receiving by sending the text command SIGNAL The detector will perform a test on the signal strength You will receive a text telling you a signal strength score of between 0 up to 30 We strongly recommend that you place the unit where you can receive a signal strength of at least 10 Anything with a score of...

Страница 4: ...7123456789 Then send this as a text message for contact no 1 2 07123456789 Then send this as a text message for contact no 2 3 07123456789 Then send this as a text message for contact no 3 If you wish to cancel a number please follow this example Example HASH 1 2 or 3 EQUALS DELETE HASH 1 DELETE Send this as a text to the simcard number in your unit PLEASE NOTE Please only send one text message at...

Страница 5: ...for your customised Message Telephone Call Alerts The Wireless Beam Alarm can be programmed to send you a call after each text alarm has been sent You will receive approximately three ring tones The unit will then hang up This is to avoid any call charges being incurred To set the alerts to ON please send the text message CALL ON The unit will reply back with CALL ON To disarm the alerts please se...

Страница 6: ...s important to have the correct Power Supply to operate this device successfully You will need a 12 volt 2 Amp supply or 12 volt battery You can purchase both of these from our website www gsm activate co uk 5 Now you have the transmitter and receiver fitted to the location you can carry out alignment You will now need to turn ON the power 6 There are two adjustments left and right and up and down...

Страница 7: ... used with the siren provided as you will get the audible alert whenever you arm or disarm the alarm Press button A on the key fob Arms the alarm and siren will beep twice Press button B on the key fob Disarms the alarm and the siren will beep twice Again it is important to remember that when the alarm has been triggered you will need to reset the alarm using either the text command above or by us...

Страница 8: ...ld down the pairing button on the RF module for 3 seconds refer to figure 1 4 Trigger the beams by placing your hand between the beams 5 The RF module has a RED LED which will flash when pairing is complete 6 Dipswitch 1 controls siren ON or OFF 7 Dipswitch 2 controls 2G and 3G PLEASE NOTE The transmitter and receiver will work from a distance of 100 metres outside and 300 metres inside Additional...

Страница 9: ...ms Automatic monitoring system Vending machines security protection Pumping stations tanks oil or water levels Buildings and real estate Weather stations River monitoring and flood control Fridges Fish Tanks Farming equipment and security Dipswitch Settings Dipswitch 1 ON Siren ON OFF Siren OFF Dipswitch 2 ON 3G OFF 2G Note dipswitch 2 is not used on 2G only beam alarms For more technical support ...