PAGE 1

Содержание AD-SD

Страница 1: ...PAGE 1 ...

Страница 2: ...r Europe USA and Australia with excellent feedback The unit is also enclosed in a IP65 rated box which means it is perfectly weathered for outside installation and has passed testing in high temperature and below freezing conditions GSM Frequency Quad band freq 850 900 1800 1900 3g only model 2100 Mhz Power Supply Voltage 9 24 volts DC 1 Amp Max Current used in standby mode 60mA Max IP 65 Enclosur...

Страница 3: ...elling you a signal strength score between 0 up to 30 we strongly recommend that you place the unit where you can receive a signal strength score of at least 10 You will find that with a score of less than 10 the unit will be unreliable Page 3 Slide the simcard into the holder making sure that the clipped corner of the simcard lines up with the clipped corner of the simcard holder as picture above...

Страница 4: ...as a text to the simcard number of your unit then send this as a text to the simcard number of your unit If you wish to cancel a number follow this example Example hash 1 or 2 or 3 equals DELETE hash Then send this as a text to the simcard number of your unit Please send one message at a time and wait for the Auto Dialler tosend you back the text Acknowledgement NUMBERSTORED before you try to add ...

Страница 5: ...o send you a telephone call after each text alarm has been sent You will receive approximately three ring tones The unit will then hang up automatically This is to prevent call charges being incurred To set call alerts to ON please send the text message The unit will reply back call on To disarm call alerts please send the text message If the call function has been set to you will receive a text m...

Страница 6: ...een triggered To activate this mode you need to set to the position Ref page 3 This can be used to reset auxiliary equipment The Auto Dialler has two independent input s Input 1 Terminal 1 connection Negatively triggered pulled to ground Input 2 Terminal 2 connection Negatively triggered pulled to ground When the inputs are triggered the will flash 6 times to indicate that a trigger has been recei...

Страница 7: ...nitoring and flood control Fridges Fish Tanks Farming equipment and security Dipswitch settings Dipswitch 1 ON 3G Selected OFF 2G Selected Dipswitch 2 ON Relay Mode on OFF Relay Mode off To reset the unit back to factory settings you will need to send a text message Warning this will reset all of your parameters only send a reset command when necessary The green ready led will flash 8x Note Dipswi...

Страница 8: ...figure 1 4 Trigger the sensor 5 The RF module has a red LED which will flash when pairing is Complete Hold down the pairing button on the RF Module for 3 seconds refer to figure 1 7 Trigger the door switch 8 The RF module has a RED LED which will flash when pairing is Complete Once the sensors are paired you can now send a text command to activate the alarm This will activate the alarm This will d...

Страница 9: ... OFF electrical equipment Alternatively it can be used for resetting your alarm system The relay can be manually activated by text message commands or it can be set to pulse for 20 seconds when an input has been activated refer to page 6 PAGE 9 Please make sure you supply a 9 24 volts DC from the battery terminals via a 2 amp fuse for alarm panel installations For more technical support please bro...