Series GNP20C GNP30C GNP30T

Gas Engine-Driven, Self-Priming, SAE Mount,

G-POWER PRO Centrifugal Pumps

Rev. A

Installation, Operation, Repair and Parts Manual

G-power

 

Self-Priming Centrifugal Pumps handle big, high-capacity, liquid transfer jobs with ease. Use them for transferring 

water, liquid fertilizers, and other chemicals compatible with pump materials. Make short work of other farm jobs: filling nurse 
tanks, watering seedbeds and transferring liquids. This self-priming model makes it ideal for de-watering applications.

GNP20C

Close-Coupled, Gas Engine-Driven

Self-Priming Centrifugal Pump

 GNP30C

Close-Coupled, Gas Engine-Driven

Self-Priming Centrifugal Pump

GNP30T

Close-Coupled, Gas Engine-Driven

Self-Priming Centrifugal Trash Pump

Description

California Proposition 65 Warning 

 – This product and related accessories contain chemicals known to the State of California 

to cause cancer, birth defects or other reproductive harm.

WARNING: Do not pump flammable or explosive fluids such 

as gasoline, fuel oil, kerosene, etc. Do not use in explosive 

atmospheres. The pump should be used only with liquids 

that are compatible with the pump component materials. 

Failure to follow this warning can result in personal injury 

and/or property damage and will void the product warranty. 

1. DO NOT EXCEED recommended speed, pressure and 

temperature (140° F) for pump and equipment being used.

2. BEFORE SERVICING, drain all liquids from the system and 

flush. Remove the spark plug wire from the spark plug 
before servicing the pump or engine.

3. Secure the discharge lines before starting the pump. An 

unsecured line may whip, causing personal injury and/or 
property damage.

4. Check hose for weak or worn condition before each use. 

Make certain that all connections are tight and secure.

5. Periodically inspect the pump and the system components. 

Perform routine maintenance as required 
(see Maintenance section).

6. Protect pump from freezing conditions by draining liquid 

and pumping a permanent-type automobile antifreeze 
containing a rust inhibitor through the system, coating the 
pump interior. A 50% mixture with water is recommended.

 7. Do not operate a gasoline engine in an enclosed area. 

Be sure the area is well ventilated.

WARNING: Gasoline is a highly combustible fuel. The 

improper use, handling, or storage of gasoline can be 

dangerous. Never touch or fill a hot engine.

8. Use only pipe, hose and fittings rated for the maximum psi 

rating of the pump.

9. Do not use these pumps for pumping water or other liquids 

for human or animal consumption.

 .............................................1 0 8  f e e t

Suction Head: ..................................... 26 feet

Max. Waterflow .................................158 GPM
Ports: ........................................... 2" NPT Inlet

2" NPT Outlet

Engine: ............................................... LCT208

 .............................................  89    f e e t

Suction Head: ..................................... 26 feet

Max. Waterflow .................................227 GPM
Ports: ........................................... 3" NPT Inlet

3" NPT Outlet

Engine: ............................................... LCT208

 ....................................................99   f e e t

Suction Head: ............................................23  feet

Max. Waterflow ........................................110GPM
Ports: ................................................. 3" NPT Inlet

3" NPT Outlet

Engine: .................................................. ... LCT208

General Safety Information

g

-

P o w e r

A m e r i c a

Содержание GNP20C Series

Страница 1: ...ure 140 F for pump and equipment being used 2 BEFORE SERVICING drain all liquids from the system and flush Remove the spark plug wire from the spark plug before servicing the pump or engine 3 Secure t...

Страница 2: ...h engine oil make sure the engine is stopped and placed on a stable level surface Use oil recommended for ambient air temperatures that the engine will be running at See chart below Change oil accordi...

Страница 3: ...ssembly process orientation and order of part assembly to ensure an easy assembly process 1 Pull spark plug wire off spark plug for safety considerations Remove the four bolts holding the casing to th...

Страница 4: ...CLEAN AND LUBRICATED NEVER RUN THE SEAL SURFACES DRY 5 Place the key into the keyway of the crankshaft making sure it is seated properly Lubricate the crankshaft slightly with WD 40 LPS or equivalent...

Страница 5: ...psed suction hose Suction inlet hose should be same diameter as inlet port fitting Check hose for kinks Blocked or clogged inlet Inspect basket strainer and clear any debris from screen Impeller plugg...

Страница 6: ...11 2270 0112 Washer 12 4 19708 Hex Bolt M8x25 13 2 N A O ring 23x3 5mm 14 2 3240 0008 Plug 15 1 2404 0409 Outlet Flange 16 1 N A Check Valve 17 1 2404 0405 Inlet Flange 18 7 2210 0120 Hex Bolt M8x20 1...

Страница 7: ...2 Washer 4 2250 0008 Hex Nut 1 1 N A Pump Body 2 2 N A O ring 23x3 5mm 3 2 3240 0008 Plug 4 6 2280 0006 T type Screw 5 6 N A O ring 5x2 65mm 6 1 N A Check Valve 7 1 N A 8 1 0402 1543 Impeller 9 1 N A...