background image

 

18 

STORAGE/TRANSPORT PROCEDURES 

 

 

When transporting or storing this generator for extended time: 

 

Storage Time 

Recommended Storage Procedure 

(which will help prevent difficult starts) 

Less than 1 month 

No storage procedure required. 

1 to 2 months 

Fill with fresh gasoline and add gasoline stablizer 

2 months to 1 year 

Empty the fuel tank. (See Emptying the Fuel Tank in the Maintenance/Care section.) 

1 year or more 

Empty the fuel tank. (See Emptying the Fuel Tank in the Maintenance/Care section.) Disconnect the spark plug. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

Never place any type of storage cover on this generator while it is still hot. 

Содержание GN1750D

Страница 1: ...s manual provides important information on proper operation maintenance Every effort has been made to ensure the accuracy of this manual These instructions are not meant to cover every possible condit...

Страница 2: ...een poweramerica com service and follow the instructions to register online following the instructions to register online Option 2 Fill out the form on the Warranty Card include in the box and return...

Страница 3: ...Generator 11 Step 1 Verify Oil Level 11 Step 2 Verify Gas Level 11 Step 3 Ground the Generator 11 STARTING THE GENERATOR 12 USING THE GENERATOR 13 AC Usage 13 DC Usage 14 SWITCHING BETWEEN GASOLINE P...

Страница 4: ...en to be defective in materials or workmanship under normal use during the ONE 1 YEAR warranty period Warranty repairs or replacements will be made without charge for parts or labor Parts replaced dur...

Страница 5: ...less AND may be present even if you do not see or smell gas Breathing this poison gas can lead to headaches dizziness drowsiness loss of consciousness and eventually death Usage This generator is not...

Страница 6: ...oors where gasoline fumes may reach flames and or sparks ank cap Loosen the cap slowly to relieve pressure in the fuel tank Avoid spilling fuel ank and immediately wipe it up before starting this gene...

Страница 7: ...7 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator...

Страница 8: ...ere are missing items call 1 888 834 4218 Monday Friday 8 AM 5 PM EASTERN Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETAILER Item List DC connector wires for charging 12 Volt autom...

Страница 9: ...RT DOUBLE CHECK THAT THE OIL LEVEL IS COMPLETELY FULL AND ALMOST OVERFLOWING This generator requires engine oil to function Engine oil is a major factor affecting engine performance and service life W...

Страница 10: ...ed with the generator to the Propane Tank then connect the other end to the Gas Inlet Make sure the LPG Propane cylinder is vertical and securely positioned Step 3 Ground the Generator Ground this gen...

Страница 11: ...T Use only fresh UNLEADED gasoline with an octane rating of 87 or higher Never use old and or contaminated gasoline Never use a mixture of oil and gasoline Avoid getting dirt and or water in the fuel...

Страница 12: ...o snap back 7 If the engine fails to start repeat step 6 NOTE After repeated attempts to start the engine consult the troubleshooting guide before attempting again 8 Once the engine has started GRADUA...

Страница 13: ...e rated wattage for the generator A device s rated running wattage should be listed somewhere on the device itself and or in its manual If the wattage specification for a device is not available the w...

Страница 14: ...Gauge Amps Watts 120V Watts 240V 8 wire 10 wire 12 wire 14 wire 16 wire 2 5 300 600 NR 1000 600 375 250 5 600 1200 NR 500 300 200 125 7 5 900 1800 NR 350 200 125 100 10 1200 2400 NR 250 150 100 50 15...

Страница 15: ...eck Clean X Fuel Tank Verify Gas Level X Clean X Figure 7 Recommended maintenance schedule Cleaning Generator Always try to use this generator in a cool dry place If this generator becomes dirty the e...

Страница 16: ...ed every 6 months or for every 100 hours of use or when the oil has become dirty To drain the oil from generator 1 Place a bucket underneath this generator to catch oil as it drains 2 Unscrew the oil...

Страница 17: ...rk plug An E7TC spark plug such as NGK BP6HS is recommended 4 Measure the spark plug electrode gap with a gauge The gap should be 0 020 0 028in 0 5 0 7mm See Figure 9 5 If re using the spark plug use...

Страница 18: ...h No storage procedure required 1 to 2 months Fill with fresh gasoline and add gasoline stablizer 2 months to 1 year Empty the fuel tank See Emptying the Fuel Tank in the Maintenance Care section 1 ye...

Страница 19: ...on Pull the starter You should see a spark Engine will not start Engine will not start Engine will not start Engine runs but there is no electrical output Generator runs but does not support all conne...

Страница 20: ...20 Distributed by Green Power America LLC www Green PowerAmerica com All copyright is reserved by Green Power America LLC...

Отзывы: