DIGITAL AUTOMATIC
WRIST BLOOD PRESSURE MONITOR
INSTRUCTION MANUAL
MODEL No.: MD2220/MD2222/MD2223

Version: 1

TABLE OF CONTENTS

INTRODUCTION...............................................................................1
COMPLIANCE...................................................................................1
SYMBOLS........................................................................................2
IMPORTANT NOTES.....................................................................3-5
DEVICE DESCRIPTION.....................................................................6
BATTERY INSTALLATION.................................................................7
SETTING DATE AND TIME................................................................8
BEFORE TAKING A MEASUREMENT................................................ 9
APPLYING WRIST CUFF...................................................................9
SELECT USER..................................................................................10
PERFORMING BLOOD PRESSURE MEASUREMENT......................11
RECALL AVERAGE AND PREVIOUS MEASUREMENT DATA...........12
DELETE MEASUREMENT DATA......................................................13
WHO CLASSIFICATION INDICATOR...............................................14
ABOUT IRREGULAR HEARTBEAT ...................................................15
ABOUT BLOOD PRESSURE............................................................15
TROUBLESHOOTING......................................................................16
TECHNICAL SPECIFICATION..........................................................17
APPENDIX I...............................................................................18-19
APPENDIX II..............................................................................20-22
APPENDIX III.............................................................................23-24
APPENDIX IV..................................................................................25

Содержание MD2220

Страница 1: ...LLATION 7 SETTING DATE AND TIME 8 BEFORE TAKING A MEASUREMENT 9 APPLYING WRIST CUFF 9 SELECT USER 10 PERFORMING BLOOD PRESSURE MEASUREMENT 11 RECALL AVERAGE AND PREVIOUS MEASUREMENT DATA 12 DELETE MEA...

Страница 2: ...N ISO 81060 standard relating to non invasive sphygmomanom eters Part 1 Requirements and test methods for non automated measurement types and EN 1060 standard relating to non invasive sphygmomanometer...

Страница 3: ...eaning WARNING ATTENTION Indicates a potentially hazardous situation which if not avoided could result in death or serious injury PRECAUTION IMPORTANT INFORMATION SN Serial Number Manufacturer Type BF...

Страница 4: ...o not take measurements more than necessary High measurement repetition rates may cause pain numbness temporary red marks or bruising to the arm wrist due to blood flow interference If you have any of...

Страница 5: ...oid the user warranty Do not subject the device to strong knocks e g dropping the unit on the floor extreme in temperature high humidity direct sunlight dust or chemicals This may damage the device Th...

Страница 6: ...ced on top of it Do not place the arm cuff over heavy clothing e g a jacket or sweater sleeve as the blood pressure monitor will not be able to take a proper measurement and there is an elevated dange...

Страница 7: ...zing Releasing Air Average Data User 1 User 2 Memory Record Number and Data Systolic Pressure Diastolic Pressure Pulse Rate Severe Hypertension Moderate Hypertension Mild Hypertension High Normal Norm...

Страница 8: ...e a choking hazard to children Store the batteries out of the reach of children In case battery fluid leaks do not touch the battery fluid Avoid skin contact e g put on protective gloves and clean the...

Страница 9: ...to set the current Day 7 Press key to confirm and then HOUR will start to blink 8 Press M key to set the current Hour 9 Press key to confirm and then MINUTE will start to blink 10 Press M key to set...

Страница 10: ...asurements during stressful conditions Avoid taking measurement while you are physically tired or exhausted Remain still and do not talk during the measurement Position the cuff at heart level through...

Страница 11: ...measurement data for 2 users User 1 and User 2 Every time you complete the measurement the device automatically stores the measurement result 1 If the device is in OFF status press key to turn on the...

Страница 12: ...measuring the blood pressure and the pulse rate while the cuff is deflating Releasing air indicator the corresponding pressure bar indicators and the current cuff pressure appear on the display As so...

Страница 13: ...y View average measurement data of the last 3 measurements 1 Press M key to turn on the device and view the average measurement data View previous measurement data 2 Press M key to view previous measu...

Страница 14: ...hows CL and 00 and the selected record is deleted 4 The display will automatically return to view the previous measurement data B Delete all memory records 1 Press M key to view the average measuremen...

Страница 15: ...as a standard to assess high blood pressure regardless of the age Reference Material Journal of Hypertension 1999 Vol 17 No 2 The WHO Classification Indicator is a feature which provides a snapshot of...

Страница 16: ...nst the walls of the arteries Systolic pressure occurs when the heart contracts Diastolic pressure occurs when the heart expands Blood pressure is measured in millimeters of mercury mmHg One s natural...

Страница 17: ...ERROR code 3 E3 appears No pressure is detected The cuff may not fasten properly or too loose Reapply the cuff and fasten the cuff correctly ERROR code 5 E5 appears The cuff is over inflated Blood pr...

Страница 18: ...sers MD2220 240 120 x 2 users MD2222 MD2223 Dimensions Approx 2 8 x 3 1 x 1 3 70 x 80 x 32mm Wrist Cuff Circumference Range 5 3 8 5 13 5 21 5cm Operating Temperature 41 F to 104 F 5 C to 40 C Operatin...

Страница 19: ...The Sphygmomanometer MD2220 MD2222 MD2223 uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equip...

Страница 20: ...is intended for use in the electromagnetic environment specified below The customer of the user of Sphygmomanometer MD2220 MD2222 MD2223 should assure that it is used in such an environment Power fre...

Страница 21: ...Sphygmomanometer MD2220 MD2222 MD2223 should assure that it is used in such an environment Portable and mobile RF communications equipment should be used no closer to any part of the Sphygmomanometer...

Страница 22: ...21...

Страница 23: ...netic site survey should be considered If the measured field strength in the location in which the Sphygmomanometer MD2220 MD2222 MD2223 is used exceeds the applicable RF compliance level above the Sp...

Страница 24: ...magnetic environment in which radiated RF disturbances are controlled The customer or the user of the Sphygmomanometer MD2220 MD2222 MD2223 can help prevent electromagnetic interference by maintaining...

Страница 25: ...24...

Страница 26: ...termined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the...

Страница 27: ...ability to five 5 years from the original date of purchase at retail This warranty extends only to the original retail purchaser and is not transferable G LAB s sole liability from this warranty is li...

Отзывы: