Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
Attention:
After every 16 devices, the fixtures must have a renewed connection with the power mains.
OPERATION
After you connected the effect to the mains, the OFL-72 W/A IP65 starts running.
Stand Alone-operation
In the Stand Alone mode, the OFL-72 W/A IP65 can be used without controller.
Disconnect the OFL-72 W/A IP65 from the controller.