Different setup screens are provided in the configurator for the various functions and settings of the MCT. It is
important to note; however, that the loop controllers must be set up independently of the configurator, via the
loop controller itself. Refer to the operating manual for the model loop control being used for information on
how to access the various input and output settings in order to properly set up the controller to match the
application.
IMPORTANT: Once all
configuration settings are made, you must select “Exit” from the File menu to exit the
Configurator prior to cycling power to the MCT. All configuration files are written upon exiting
the Configurator. Do not cycle power prior to exiting the Configurator or settings will be lost
and the MCT will not operate properly once the runtime application starts.
Upon exiting the Configurator application and cycling power to the MCT, the runtime application
will be automatically started on the next boot sequence.
To assist in setup and documentation of the MCT
, see the “MCT-CM Configuration Worksheet” Excel
file provided on the Future Design Controls website. This document provides setup and configuration
forms and templates for all of the MCT-CM configuration parameters.
http://www.futuredesigncontrols.com/MCT.htm
4.1 IO Settings
The ‘IO Settings’ screen is accessed from the Setup menu. It is the primary configuration screen for the MCT
providing entries for setting the number of control loops and monitor points, number of analog and digital inputs
and outputs, number of process alarms as well as the number of system events available in the system. It also
provides the ability to set the auto-online feature for systems that do not use a local operator interface (HMI).
4.1.1
Setting the Number of Control Loops
The
# of Loops
field sets the number of loop controls that will be attached to the MCT. The maximum number
of control loops available is ten. If no control loops are used in the application, the number of control loops can
be set to zero. Once the number of loop controls is set, the loop configuration for each controller must be
performed so that the proper units, decimal point and set point ranges are used for each control loop.
See section 4.2 Loop Setup for information on configuring each control loop. When the MCT runtime application
is started, the MCT will automatically configure all loop view displays, trends and available log point selections
based on the settings for each control loop.
Содержание MCT-CM
Страница 1: ...MCT CM User Manual MCT CM User Manual Rev C August 2022 V1 2eCM30 V1 3eCM22 Supersedes May 2021...
Страница 20: ...MCT CM 20...
Страница 24: ...MCT CM 24...
Страница 45: ...MCT CM 45...
Страница 187: ...MCT CM 187...
Страница 227: ...MCT CM 227 A 4 Control Module Specifications Main CPU...
Страница 228: ...MCT CM 228...
Страница 229: ...MCT CM 229...
Страница 230: ...MCT CM 230...
Страница 231: ...MCT CM 231 Analog I O Card...
Страница 232: ...MCT CM 232...
Страница 233: ...MCT CM 233 Digital Input Card...
Страница 234: ...MCT CM 234...
Страница 235: ...MCT CM 235 Digital Output Card...
Страница 236: ...MCT CM 236...
Страница 237: ...MCT CM 237 Dual Communications Card Barcode and Remote Display Communication Cartridges...
Страница 238: ...MCT CM 238 A 5 Power Supply Specifications...
Страница 239: ...MCT CM 239...
Страница 240: ...MCT CM 240 A 6 Power On Delay Relay Specifications GE1A C10HA110...
Страница 241: ...MCT CM 241...