IR & RS232 Commands 

 

RS232 commands are all terminated with carriage return but no line feed. In Crestron this is 
represented by \r 

 

IR sequences involving multiple key-presses require each successive key to be pressed within 2 
seconds  
 

User Control 

IR 

RS232 

Action 

Comments 

IN 

fa_in 

System fully in 

 

HOME 

 

Moves to telescope 
extended, swivel 
centred position 

Swivel moves to centre if 
already rotated 

OUT 

 

Similar to HOME 
but swivel will not 
move  

Swivel will not move 

PRESET 

fa_preset 

Moves to telescope 
extended, swivel at 
intermediate 
viewing angle 
“PRESET”  

 

fa_a 

Moves to telescope 
extended, swivel at 
intermediate 
viewing angle “A”  

 

fa_b 

Moves to telescope 
extended, swivel at 
intermediate 
viewing angle “B”  

 

fa_c 

Moves to telescope 
extended, swivel at 
intermediate 
viewing angle “C”  

 

fa_left 

Moves to telescope 
extended, swivel at 
maximum left 

Maximum angle achievable 
relative to the current maximum 
arm out setting 

fa_right 

Moves to telescope 
extended, swivel at 
maximum right 

Maximum angle achievable 
relative to the current maximum 
arm out setting 

STOP 

fa_stop 

Stop mechanism 

 

 
 