Futek USB200 Series Скачать руководство пользователя страница 1

Troubleshooting Guide

Sensor Solutions Source

Load · Torque · Pressure · Multi Axis · Calibration · Instruments · Software

www.futek.com

USB200 Series

High-Resolution USB Output Devices

Содержание USB200 Series

Страница 1: ...Troubleshooting Guide Sensor Solutions Source Load Torque Pressure Multi Axis Calibration Instruments Software www futek com USB200 Series High Resolution USB Output Devices...

Страница 2: ...ice Please visit http www futek com salesterms for complete terms and conditions 10 Thomas Irvine CA 92618 USA Tel 949 465 0900 Fax 949 465 0905 www futek com Important Tips 3 Frequently Asked Questio...

Страница 3: ...free trial provides the Full Version of SENSIT for a period of 14 days If a purchase code is entered the Full Version will remain permanently Sensors with Teflon cables are more prone to wiggling out...

Страница 4: ...nifies that the calibration initialization process has been completed b Are all three LED s lit when plugging in the USB The green LED signifies that the USB kit is properly powered through the USB po...

Страница 5: ...I CLOSE THE PROGRAM If any software communicating with USB closes unexpectedly a reset will be needed for the USB device as it may be stuck in an unknown state Unplug and re plug the device to perform...

Страница 6: ...he DLL bit match that of your LabVIEW program i e 32 bit DLL for 32 bit LabVIEW In LabVIEW 2015 the FUTEK DLL must be in the same directory as LabView exe You can get drivers from FTDIchip here http w...

Страница 7: ...gnal the word Error will instead be sent SENSIT will generate this error when it receives the string word Error instead of an integer number Possible causes would be if the internal USB instrument cal...

Страница 8: ...If your version of Excel is a click to run an internet search of this version of Excel can provide more information Issue can be solved by saving the test results in CSV or TXT format or downloading f...

Страница 9: ...e is no row at position XXXXXX This is caused by a threading issue during Live Graphing This issue has been resolved in later updates of SENSIT The latest version should be downloaded and installed Fi...

Страница 10: ...version and operating language i e Windows 7 64 bit with Microsoft Excel 2010 English language 3 Description of what you were trying to perform in the SENSIT Software and when you received the error...

Страница 11: ...11 Figure 7...

Страница 12: ...10 Thomas Irvine CA 92618 USA Tel 949 465 0900 Fax 949 465 0905 www futek com...