75
System Type selection
The T16IZ is for 2.4 GHz only. The system can
be changed from among 6 choices: FASSTest
18CH, FASSTest12CH, FASST MULTI, FASST
7CH, T-FHSS, S-FHSS. It is FASSTest18CH and
FASSTest12CH which can be chosen by R7108SB
set. The method of selection is on the next page.
*If you change the System type, other model data is not reset.
*After any change, remember to test the model and fully
check servo direction and motion.
*Analog servos cannot be used with the R7108SB in the
FASSTest12CH mode.
System type
System mode setting, Receiver link
Receiver linking
The receiver will only be controlled (without being
affected by other transmitters) by the transmitter it
is linked to. When using a receiver other than one
purchased as a set, linking is necessary.
Moreover, a re-link is required when a new model
is added by model selection, and at the time of
system type change.
Dual receiver function (only FASSTest 18CH )
Dual receivers can be linked with the T16IZ.
Two receivers are recognized individually by ID
numbers. For example, in R7108SB, CH output
setting function is used, by setting the first as as
"1-8CH", and setting the second as "9-16CH".
Two sets of receivers can be used as a set in the
model, allowing you 16 channels. Separate fail-safe
voltage can be set to each receiver.
However, telemetry cannot be used for the 2nd
receiver.
Battery fail-safe voltage setup (FASSTest /T-FHSS
mode only)
The voltage at which battery fail-safe activates can
be set when you link. (3.5-8.4 V) The receiver
memorizes the setting as it was at link.
Since power consumption varies with battery type,
servos and condition, please select the fail-safe
activation voltage for your own model.
● Select [System type] in the Linkage menu
and access the setup screen shown below.
P.39
Linking method
Cases when linking is necessary:
・
When using a receiver other than the initial setting.
・
When the communication system was changed.
(FASSTest18CH
↔
FASSTest12CH etc.
)
・
When a new model was created by model
selection.
Telemetry function (FASSTest /T-FHSS mode only)
To use the telemetry function, set “Telemetry” to
“ACT”.
DL Interval (FASSTest mode only)
When a telemetry function is enabled, the receiving
interval (down-link interval) of sensor data can be
changed.
If a DL interval is increased, the response of the
sensor data display becomes slower, but stick
response will improve.
●Return to
Linkage
menu
*FASST MULTI/FASST 7CH cannot be selected for Europe.