2. GRAPH FUNCTIONS
2-20
SIZE1 - SIZE3 menu
The following menu items change according the measurement mode.
• [Specific Area] measurement mode: Since the [SIZE2] and [SIZE3] menus are en-
abled, the fish length graph can be set individually. For example, the [SIZE2] fish
length graph is set in the [SIZE2] menu.
• Measurement mode other than [Specific Area]: The menu settings for the [SIZE1]
menu are reflected to the fish graph.
1. Click the [Advance Settings] icon (
) on the InstantAccess bar™, then click the
icon (
) to show the [Advanced Settings] menu.
2. Click [Fish Size] to show the [Fish Size] settings on the right-side of the window.
3. Referring to the table below, select the measurement option to change, then
change the settings as required.
4. Click the [OK] button to save settings and finish, or click the [Cancel] button to re-
store previous settings and escape.
Menu item
Description
[Graph Scale End]
Sets the maximum fish size to
be displayed on the graph.
[Distributed Scale Start] Sets the percentage of distribution at which data starts appearing on the
graph. (See the above figure.)
[Distributed Scale End]
Sets the percentage of distribution at which data stops appearing on the
graph. (See the above figure.)
[Graph Peak]
[1st]: Shows only the highest peak measurement.
[1st + 2nd]: Shows the two highest peak measurements.
[1st + 2nd + 3rd]: Shows the three highest peak measurements.
Set the number of peak measurement to display on the graph.
[Emphasis Type]
Sets the degree of peak emphasis, among the following options. The larger
the number, the longer the bar that shows peak
• [Off]: Disable peak emphasis processing.
• [Type 1]: Emphasize small peaks centering on 1st peak.
• [Type 2]: Each peak is emphasized, multiple peaks are separated and
emphasized.
• [Type 3]: Emphasize large peaks centering on 1st peak.
[Offset]
Compensates for error in displayed fish size. For example, if the displayed
value is smaller than the actual value, enter a positive value.
FSS-3BB[0252470-xx.xx]
[Distributed
Scale End]
[Distributed
Scale End]
Vertical Scale Settings
[Distributed
Scale Start]
[Distributed
Scale Start]
[Graph Scale End]
[Graph Scale End]
Содержание FSS-3BB