5. MAINTENANCE AND TROUBLESHOOTING
5-6
Processor Unit
System Error
P01
The voltage of the battery inside the Pro-
cessor Unit is low. Turn the equipment
off, then contact your local dealer to re-
quest replacement of the battery.
3
P02
The fan is in the Processor Unit is rotat-
ing too slowly. Turn the equipment off,
then contact your local dealer to request
replacement of the fan.
4
P03
Multiple alike IP addresses found. Turn
the equipment off, then contact your lo-
cal dealer for advice. (IP address setup
cannot be changed from this equipment.
Change the IP address at the external
device.)
5
Transceiver Unit
System Error
T01
Communication error between the
Transceiver Unit and Processor Unit.
Turn the equipment off, then contact
your local dealer for service.
2
T02
The rotating speed of the fan in the
Transceiver Unit is abnormal. Turn the
equipment off, then contact your local
dealer for service.
6
T03
Overcurrent detected in the Transceiver
Unit. Turn the equipment off, then con-
tact your local dealer for service.
7
T04
TX voltage error detected in the Trans-
ceiver Unit. Turn the equipment off, then
contact your local dealer for service.
8
T06
Transducer connection error (short cir-
cuit) detected. Turn the equipment off,
then contact your local dealer for ser-
vice.
9
Error
Icon
Error name
Error
code
Reason, remedy
Priority
Order
Содержание FSS-3BB
Страница 12: ...SYSTEM CONFIGURATION x This page is intentionally left blank...
Страница 98: ...4 ADVANCED SETTINGS 4 20 This page is intentionally left blank...
Страница 110: ...5 MAINTENANCE AND TROUBLESHOOTING 5 12 This page is intentionally left blank...
Страница 119: ......
Страница 120: ......
Страница 121: ......