1. OPERATION
16
Fish Type
1) Select [ACCU-FISH], [Fish School],
[Bottom Fish(Only BL)] or [Bottom],
then press the
ENTER
key.
For [ACCU-FISH] go to step 2). For
other choices go to step 6).
2) Select [From] (under
[Fish Type]), then
press the
ENTER
key.
3) Set the minimum fish
length, then press the
ENTER
key.
4) Select [Span] (be-
low [Fish Type]),
then press the
EN-
TER
key.
5) Set the width of the
alarm, then press the
ENTER
key. Go
to step 8. (The maximum measure-
able fish length is 78 inch.)
6) Select [Fish Level], then press the
ENTER
key.
7) Select the echo strength that triggers
the alarm, referring to the description
below.
[
Weak
]: Echoes stronger than light-
blue trigger the alarm.
[
Medium
]: Echoes stronger than yel-
low trigger the alarm.
[
Strong
]: Echoes stronger than red
trigger the alarm.
8) Select the [From] that is below
[Depth], then press the
ENTER
key.
9) Enter the width of the alarm, then
press the
ENTER
key.
The alarm marker appears at the
starting point for the alarm. (The
marker appears only when the corre-
sponding alarm is active.) The starting
depth for the ACCU-FISH
TM
and [Fish
School] alarms is the transducer posi-
tion. For the [Bottom Lock] alarm the
starting depth is the distance from the
bottom.
10)Select [Span], then press the
ENTER
key.
11)Enter the alarm width, then press the
ENTER
key.
Water temperature
1) Select [Inside] or [Outside] as appli-
cable, then press the
ENTER
key.
2) Select [From], then
press the
ENTER
key.
3) Enter the starting tem-
perature for the alarm,
then press the
ENTER
key.
4) Select [Span], then
press the
ENTER
key.
5) Enter the width for the
alarm, then press the
ENTER
key.
Bottom Type
Select [Rock], [Gravel], [Sand] or [Mud],
then press the
ENTER
key.
ACCU-FISH,
Fish School
alarms
Bottom Fish
alarm
Alarm marker
- ACCU-FISH, Fish School, Bottom: Left side
- Bottom lock: Center
Starting
depth
Alarm range
(width from
starting depth)
ACCU-FISH,
Fish School
alarms
Bottom Fish
alarm
Содержание FCV-588
Страница 1: ...B R I L L GAIN...
Страница 72: ...D 1 13 Jan 2012 Y NISHIYAMA...
Страница 73: ...D 2 13 Jan 2012 Y NISHIYAMA...
Страница 74: ...D 3 13 Jan 2012 Y NISHIYAMA...
Страница 75: ...D 4 13 Jan 2012 Y NISHIYAMA...
Страница 76: ...D...