2. GRAPH FUNCTIONS
2-7
2
2.2.7
How to change fish size graph settings
Several aspects of the graphs can be changed from the [Fish Size] menu.
Fish Size menu
1. Click the [Advanced Settings] icon (
) from the InstantAccess bar™, then click
the [Advanced Settings] icon (
) to show the [Advanced Settings] window.
2. Click [Fish Size] to show the [Fish Size] settings on the right-side of the window.
3. Referring to the table below, select the measurement option to change, then
change the settings as required.
Item
Description
[Auto Specific Area]
This menu item is valid when the measuring mode is [Spe-
cific Area].
z
[Auto Specific Area]: Sets whether to use the automat-
ic adjustment function of the measuring range during
the specific area measuring mode. Up to three mea-
surement ranges can be set, but automatic adjustment
is performed only for the measuring range selected
with [Target Measurement Area] below.
• [Auto Depth]: Even if the depth at which a single fish
is present changes after setting the measurement
range, the measurement range is automatically
shifted to a position with a large number of single
fish. During automatic adjustment function, the posi-
tion and size of the measurement marker can be
changed.
• [Auto Area]: The measurement range that was set is
deleted once and the measurement range is auto-
matically set to the place where the number of single
fish is large. During automatic adjustment function,
the position and size of the measurement marker
can not be changed.
• [Off]: Disable automatic adjustment
z
[Target Measurement Area]: Available when [Auto
Specific Area] is set to other than [Off]. Select the mea-
surement area to use with the automatic area adjust-
ment feature.
z
[Updating Cycle]: Available when [Auto Specific Area]
is set to other than [Off]. Set the updating interval for
automatic area adjustment, from among, High (5 s),
Medium (15 s), and Low (30 s).
FCV-38[0252473-xx.xx]