4. ADVANCED SETTINGS
4-19
4
4.7.6
Calibration Settings menu
The [Calibration Settings] menu calibrates the FCV-38 system. For further details see
section 5.4.
4.7.7
Stabilization menu
The [Stabilization] section of the [System] menu mainly compensates for heaving. See
the Notes below to enable use of this function.
Note 1:
This function requires connection to a Satellite Compass
™
. If data from the
compass is lost or interrupted, the function is disabled.
Note 2:
To use stabilization, set output data on the Satellite Compass
™
as shown be-
low. See the operator’s manual for the Satellite Compass
™
.
• Output sentence: ATT (GPatt), HVE (GPhve)
• Baud rate: 38,400 bps
• Output interval: 25 ms or less
• Version (SC-50/110 only): IEC ED1
Note 3:
This function is unavailable if [KP Input] is set to [On] at installation.
Menu item
Description
[Stabilization]
Turns heaving compensation on or off. Turn it on when seas are rough, to
get stable echoes, regardless of sea conditions. When turned on, the sta-
bilization icon (
) appears in the [Picture Advance] section of the
header.
Note:
Where data from the Satellite Compass
™
is interrupted or lost, the
stabilization icon is overlaid with a cross to indicate that it is not in use.
When data from the Satellite Compass
™
is received again, the cross is re-
moved.
FCV-38[ver 0252473-xx.xx]
Motion Sensor