4. MAINTENANCE, SERVICE RELATED INFORMATION
4-3
4.4
Cable Types
The table below shows the types of coaxial cables used in the transceiver unit.
4.5
Periodic Replacement Parts
The transceiver unit has no periodic replacement parts. The life of the fan is better
than 10 years.
4.6
Connection With the Transceiver Unit
Reference information for connecting with the transceiver unit is shown in the table be-
low. Arrange other units, work materials, etc. according to equipment and environ-
ment.
Signal
name
Connection
point 1
Connection
point 2
Cable
type
TX-IF
SPU Board (J714)
RF-CONV Board (J722)
SP
2 SS L270
RX-IF
SPU Board (J715)
RF-CONV Board (J723)
SP
2 SS L300
Rx_RF
RF-CONV Board (J729)
LNA Board (J742)
SMA-PL/PS L245
HPA_in
RF-CONV Board (J727)
HPA Board (J733)
SMA-PL/PS L475
HPA_FB
RF-CONV Board (J726)
HPA Board (J732)
SMA-PL/PS L245
Name
Type
Code No.
Remarks
Antenna Unit (Radia-
tor)
XN20AF
-
6.5 ft
XN24AF
-
8 ft
Antenna Unit (Gear
Box)
RSB-103
-
Processor Unit
EC-3000
-
Monitor Unit
MU-231
-
Control Unit
RCU-025
000-027-614 Standard type
Power Supply Unit
PSU-007
000-081-238 440 VAC, 60 Hz, 1.2A
FR-9 Termination
FR-9-00
001-102-740
Installation Materials
CP03-16400
000-086-743
w/CP03-16401
CP03-16410
000-086-744
Flexible waveguide,
20 m, w/CP03-16411
CP24-02120
000-024-925
For EC-3000
CP24-02200
000-027-668
For RCU-025
Accessories
FP24-00603
001-285-760
For EC-3000
FP24-00701
001-418-340
For RCU-025
Waveguide Twist
RWA-1050 C 109
001-304-660
Rectangular Guide
Clamp
OP03-148
008-477-540
Waveguide Drain
03-009-0360
001-351-950
H-type Waveguide
Clamp
CP03-00600-W
008-198-420
E-Bend Waveguide
RWA-1030 B-107
001-304-640
Содержание FAR-3220Z