1. INSTALLATION
1-5
1.3
Distributor Unit DS-610
The distributor unit can be mounted on the deck or on a bulkhead. Consider the fol-
lowing points when selecting a mounting location.
• Select a location which is both well ventilated and low in humidity to keep the unit
cool.
• For bulkhead mounting, be sure the mounting location is strong enough to support
the weight under the continued vibration normally encountered on the vessel.
• A magnetic compass will be affected if the distribution box is too close. Observe the
compass safe distances to prevent disturbance to the magnetic compass.
1. Screw in lower hex. bolts so there is 5 mm clearance between bottom of screw
head and bulkhead.
2. Hang the unit on the bolts, then tighten the bolts.
3. Fasten the unit with upper hex. bolts.
Fixing hole
2- 12
620±1 (24.41”)
450±1 (17.72”)
98 (3.86”)
12 (0.47”)
R6
630 (24.80”)
(37) (1.46”)